Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. Ted808

    price of petrol up n up? Do you need to put hourly rate up?

    Has anyone put their prices up due to the rise in fuel over the last month or so? Seriously it's 10p more than in February . I do quite few small trips and allow about £3 per journey. But think I need to up it. How do you other ,one man bands, calculate the fuel costs? Any tips? :rolleyes:
  2. Ted808

    WATTS, bath mixer, unable to regulate, bimetallic, NIGHTMARE / tales of oddities

    Applogies guys it's a long story....... Fella has a bath/shower mixer- apparently a fancy one that was second hand. He's an antique dealer. Problem is water is too cold to run a bath- thermostatic cartridge right? After some faffing I got hold of manufacturer and dismantled body removed...
  3. Ted808

    Scummy F+E tank in a tiny kind of loft space.

    I've seen brown scum in Fe tanks but not this white scum. I would replace tank after PF but what would you guys do? I've had so much trouble with old systems.... Air , noise, pumps failing, scuz playing havoc after drain down... What's the protocol for whipping Fe out and converting to sealed...
  4. Ted808

    greenstar 24RI .ap hose insecure

    Hey Guys do you come across this often? I've had it twice now and not sure why it's happening. I found it on a service /inspection of the boiler, which is still working fine- which is the puzzling bit. Any clues and what a pain to try top replace, as you can't get to the AP hose connection...
  5. Ted808

    gravity system, loud noises

    Old boiler was replaced with Valiant 425. The customer is complaining- rightfully so, sometimes when the heating is on there is very loud noises from the radiator/pipes - that wasn't there before. I've been back and rebalanced the system, a few times - as it seems to keep loosing the...
  6. Ted808

    ever seen this? plastic pipe most probably from around 15+years ago

    Is this old Hep20 with brass push fittings and is is ok to use with the new white hep20 fittings and inserts? Cream pipe22mm and dark brown 15mm. Any thoughts guys? The 15mm says CARTOL ACORN-BP. I need to reroute, would like to use hep20 as replacement .
  7. Ted808

    hoodwinked by customer, greenstar vs biasi

    'been drafted in on day rate to sort out where previous plumber/builder/engineer left off- he took the money and run- apparently?! Anyway, boiler has been moved from loft to kitchen- well, place is a build site- walls are being plastered, floorboards are up all over the show, etc. Green star is...
  8. Ted808

    Vaillant teci helpline

    Well blow me socks off - got my mobi bill and I've been stung! Seems there's a few things that have just changed - without me knowing they would. Might have my head in the poxy little space between the bath and the loo! I checked mobile bill and it's £20 more- so I had to log in to the mobi...
  9. Ted808

    wondervalve, flow restrictor and iso in one!!

    Anyone used these yet? wondering about wondervalve- pricey too.
  10. Ted808

    F85 on brand new Vaillant, ecotec plus, 418, STRESS

    WHat is going on here? boiler is full of water- i CHECKED boiler downstairs in the kitchen, cylinder upstairs in airing cupboard- Y-plan Rads downstairs on drops, lots of air in system- seems extra difficult to bleed (being gravity) 3 DROPS - 5 rads downstairs, 3 upstairs - AV above pump...
  11. Ted808

    greenstar occasional reset but repeatedly, every few weeks- for a few months

    Is this something that is a known fault on worc gs's? Haven't been there yet just a phone call- any advice what to look for? Cheers
  12. Ted808

    torque adjustable wrench, as a plumbing tool

    Hi guys, ever heard of one of these? Does anybody use one?
  13. Ted808

    viessmann standard flue

    I have a brand new, in the box, - viessmann standard flue, any offers? Suitable for Viessmann vitodens 100 series. I'm in North London :yesnod:
  14. Ted808

    bathroom extractor fan

    Hi Guys Can I wire in a bathroom extractor?. Cables are in solid ceiling. Can only access cord pull for light and light fitting- seems like there's L N E in the light fitting and L SL in the fitting - the fan has a timer I think I got the wrong one. Cheers ted :willy_nilly:
  15. Ted808

    electric heating . Elson. HELP

    This is right out of my depth. Original problem was that the overflow had been running for so long and so much that the brickwork has started crumbling. Changed the valve. Tested the controls, check seemed to work. Although I thought that the emersion was wired into the shower pump, and the...
  16. Ted808

    twin Vaillant 428's - odd problem

    Job presented as a leak- aav dribbling! Temp shut it- going back to replace. This is an open vented system, with twin Vailant 428 boilers. Anyhows boiler has F23 fault on - I reset and fired up... Made a helluva racket and went to F22! Checked f+e ... It's full even a bit too full? I drained...
  17. Ted808

    Wiring questions... old prog? new boiler

    Hi guys... This always seems to get me and I've done the Honeywell, wiring day out, a year back or so.... So I put in a new boiler - was going for a Valliant but due to space had to go for the Glow worm Energy - heat only ... long story short... I wired it as recommended but I when I rang teci...
  18. Ted808

    viessmann 111: hot water issues

    :uhoh2: Anyone know the ins and outs of this little boiler? Cust has HW issues, basically, ?? dirt in the system diagnosed by Viessmann, since then had power flush of CH system but not boiler! (installer back to do this- plonker also had put MF on flow!) Had P2P changed twice...
  19. Ted808

    BG 330- ?glowworm HE?

    Hi customer has had F1 fault on this boiler. Checked flue . condense and gap on electrodes~ had to replace them as gasket ripped so can't only buy gasket ~new electrodes. Boiler OK for a month now coming up with F1 fault code again. Any pointers appreciated. Thanks
  20. Ted808

    decommission oil boiler

    heythere! I've got a customer who has asked me to replace their oil boiler- they've just moved into a house with- oil boiler- heating and hw, emmersion hw, and two wood fires!! ANywaY the short of it is that they've arranged for a hook up to the gas main and a gas meter... now I've got to...