Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. A

    Glow worm Granada fire

    need a spare for this old appliance, ignitor coil has gone. Tried my local merchant ( No Help !) cheers
  2. A

    lpg - pipe sizing

    as above, not got my lpg ticket but can someone tell me the the rule of thumb for pipesizing, is it same as ng.
  3. A

    Unable to fit DIY pipes bought from Canada

    try someone like pirtek.
  4. A

    ferroil f30 flow sansor

    called to NO dhw unless heating is on, found flow sensor had melted internals... can someone tell me how this happens ?
  5. A

    ferroli... burner on start up..up and down flame picture ?

    i think its fan related, modena 80e. Would it be the venturi ?
  6. A

    boiler noise on start up

    oldish ferroli tempera, all good when running, customer has no issues but on start up its sounds like its going to jump off the wall.. done the usual bleeding extra but why this only when cold i.e morning start up and early evening start up... anyone got a ideas ?
  7. A

    large heating system design

    where can i get plans for a large heating design, its 7 bedrooms with 5 bathrooms, open vented system and want to keep it that way because of old steel pipework, cheers
  8. A

    Vokera Fault 75

    Can anyone tell what fault code 75 is, late call from customer last night, thks
  9. A

    zanussi..leaking hob

    spent 2hrs chasing a leak, still a drop, anyone have a bit more experience with what it could be. done all the usual, valves and p/work etc. Its a ZGG 782
  10. A

    baxi bermuda 551

    called to this old unit, no main burner, changed T/C and cleaned pilot tube and injector. Now cutting out after 10 mins. Gas Valve drops out. Checked stats etc all working fine. i suspect Gas valve but anyone on here have any other ideas, customer has very little money so its a bit of a favour job.
  11. A

    meter failure

    Called to a Alpha 35 today, no heating or DHW. Did the checks, no gas supply at CHB.Checked meter, no pressure at test point.Checked for caps etc, nowt.Called in BG they said meter had failed, ive never had this before, how common is this ?
  12. A

    Main boilers

    Hi, met a rep today in merchants from MAIN boilers, i have seen them but never intalled. Whats your opinions, rep said they are same as Baxi Duotec ?
  13. A

    ferroli..high co

    Installed a f28 (domicondens) today, came to commission and high co 0.004 ratio and 430ppm. Rang technical they said check flue ways and pressures etc, all looks fine, anyone have any other ideas need to put to bed, cheers
  14. A

    Glow worm energysaver 50

    customers CHB, cutting out on high flame setting after 20mins. Gas Pressure OK, Gas rate OK, Flame picture good but very high Co, its a water cooled burner and i have cleaned exchangers and condense today....can anyone help ?
  15. A

    myson rads. bleed screws.

    Anyone know where to get replacements quickly, over zealous customer broken 4 of 7 rads.Its the type thats sit on angle on rear of rad. thanks
  16. A

    Baxi Bahama Verticle flue required for customer

    As title, due to some dodgy conservatory fitters need a flue for above. Asked merchants and Baxi but now NO more and could not offer any alternative,customer not ready yet for new CHB, anyone help ? thanks
  17. A

    Worcester 24cdi problem

    Evening all, Called to a boiler fault today and looking for advice. Customer said boiler will not start up first thing in the morning, they have to reset several times and then off its goes. I get there all looks well, tested all the usual,found a split in one of the air pressure pipes from...
Back