Search results | Page 2
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. G

    Ideal logic stand off bracket

    Can anyone tell me how many mm this adds to the depth of the boiler Cheers
  2. G

    Pressure vessels

    When checking the charge of an expansion vessel is it okay to do with the boiler/system/cylinder full or does it need to be emptied. Does an unvented cylinder need to be completly empty of hot water before re-pressurising? I know these are basic questions, I have man flu and two kids...
  3. G

    Air pressure switch

    Why does a boiler with a longer trap such as a wb junior combi, not need an air pressure switch?
  4. G

    AR Boiler, 1 week old!

    Called out to fit a cooker in a new kitchen, noticed straight away they had a new 30kw hxi, looking for the gas pipe i noticed it was all in 15mm, about 15M in total! So decided to check inlet pressure 9mb!!!!:omg_smile: Loads of other installation faults including overflow condense pipe...
  5. G

    15 ri in kitchen cabinet

    Hi all, On worcesters own website it states a 15ri can be installed in a kitchen cupboard, do they class this as an unventilated compartment? I would just normally remove the top and bottom of a standard kitchen cupboard to get the clearences, why do worcester have to be so difficult? Their...
  6. G

    Unvented cylinders

    Hi guys, Looking for a handy book on unvented cylinders, i have my g3 qualification but just wanted an on site guide, something with a section on servicing and changing of parts would be great. Could someone please suggest a good publication and where best to obtain it from Thanks in advance
  7. G

    Servicing Ideal Icos

    Hi guys, I mostly do installs but trying to get more service type work Is there anything i need to look out for when servicing an ideal icos, iwas going to do all the usual checks and follow the service procedure in the manual. Any thoughts or comments welcome Thanks in advance
  8. G

    Ariston microgenus 23 mffi

    No hot water but central heating works Would i be correct in starting by changing dhw diaphragm Cheers guys
  9. G

    new diy member

    howdy
  10. G

    Best slimline combi?

    Have a customer who needs a combi with a max depth measurement of 310mm (back wall to front of case) for going in a cupboard. I would normally fit an ideal logic in this cae but they have a water softener. Im thinking glowworm flexicom? Love to hear your thoughts and suggestions Cheers :wink5:
  11. G

    Recommend combi with a long vertical flue

    Lookin for a cost effective combi with a long vertical flue allowance, Boiler on ground floor, flue up through airing cupboard upstairs then through loft and pitched roof, 3 bed terrace however just any elderly lady living there, so 24kw should suffice. Ideal logic perhaps? Thanks in advance
  12. G

    Combi boiler, no HW upstairs only

    I mainly do installs but a good friend of mine called with the above symptoms. Any ideas as to what i should look out for? Many thanks
  13. G

    Ideal Isar Heap of junk

    OMG what a piece of junk Family member has one, he rang on sunday to say that a pcb error has occured so i told him to order a new one Now tonight he rang and said the prv is going off outside PCB arrives tomorrow, might tell him to send it back and put money to new boiler What do you...
  14. G

    Ideal Isar PCB fault

    Hey guys, Family member just phoned me and said his ideal isar is not working and has 'PCB fault' displayed on the front. Iam not familiar with ideal boilers as i consider them a piece of junk. Is this going to be the main pcb that needs replacing? ive heard that this is a common fault with...
  15. G

    How much to charge for changing 3 port valve?

    Assuming straight forward swop, bunging system if poss Cheers
  16. G

    740mm shower tray

    About 3 years ago i had a new shower, tray and enclosure fitted, came home from work today and the wife has broken the shower enclosure. Been looking round the net and cant find a 740mm x 740mm shower enclosure, people have said you can only get 760mm. the tray does'nt look to be recessed into...
Back