Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. 5

    Ideal Vogue 26 KW combo high co reading

    HI all, finished fitting the above boiler yesterday. Straight swap, side access flue with only the elbow off the boiler. Gas pressure 21mbars on full chaff. (right by the supply) when doing the co checked, minimum was as expected- 3ppm, .0.0000, and about 7,8% Max on the other hand was 240ppm...
  2. 5

    VAILLANT ECO TEC PLUS 835

    Installed the above boiler today. They quote 14 ltrs per min hot water. Looking at the heat exchanger, it does not look any different in size to the 832 (well I know, its only 3kw more!), but comparing this to the 838, that heat exchanger is nearly double the size? and the flow rate on that is...
  3. 5

    LARGE HEAT ONLY BOILERS

    Looking to get a 40kw or 42kw heat only boiler for a largish house. already done heat loss to these values. was going to use and pressurise with external expansion vessel. Vaillant tech suggested they had a boiler to suit but i cannot find it? Anyone know if they do one ( it is for domestic use)...
  4. 5

    Vaillant 838 operations

    Fitted a Vaillant 838 Eco Tech plus combination boiler to a property 6 weeks ago. all fine. Customer called in to say that the boiler had locked out on F54 and F28. Reset did it again a few hours later, then been fine since. I attended today to check a few thing:- 1. Gas pressure at the meter...
  5. 5

    13yr old worcester 24i.

    have not been there yet, but customer complaining of no heating but has hot water. no diverter valve in the boiler and dual heat exchanger. apparently no room stat so must be linked out. they control the heating from the mechanical clock on the boiler. intend linking out the clock to confirm...
  6. 5

    External expansion vessel.

    Well, I have to go back to a heating job where the boiler expansion vessel needs changing,. For a number of reasons I intend fitting an external one. I am going to put it below the boiler using a half inch to 15mm adaptor, to 15mm then to a flexible hose to connect to the return to the boiler...