Search results | Page 2
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. gingalig

    Water in Oil tank, how to remove ??

    Hi and thanks in advance for any help, I went out to a breakdown today the tank had a fair bit of water in it when dipped with paste it indicated it to be close to the outlet but not above it, I bled the pump and what came out was pretty grim very contaminated with water approx 70mm, ( the...
  2. gingalig

    Worchester 32/50 utility boiler service

    Hi I just serviced a a 32/50 greenstar utility, my first as I’ve only just registered with Oftec. My question is are they usually so filthy. It wasn’t serviced for 2 years apparently but I’ve come away looking like a chimney sweep. It took me far to long but half the time was cleaning the thing...
  3. gingalig

    Ideal he 24 c heating but no hot water

    Hope I can get some advice, called out to a no hot water issue , I have checked theoperation of the actuator and the diverter all seems ok, I’mabout to order a DHW flowswitch , the boiler fires forheating and the heating works fine, and a very small amountof hot water will arrive at tapsbut then...
  4. gingalig

    Parts supply for oil boilers

    Hope some one can help , I’ve recently passed my OFTEC and I’m looking for the best online supplier of parts , I use BES and local merchant for my Gas stuff and wondered if there are any specific oil boiler parts suppliers as I would like to build up my rolling stock. Thanks in advance
  5. gingalig

    PRV terminating over alley second floor

    Hi , Here again, looking for a little advice, I have my probationary Gas Safe interview in the morning and the inspector is meeting me at a property for a service on a worchester 24 cdi, I went to have a brief look today and saw that the PRV is terminating above the communal alleyway, the...
  6. gingalig

    Ideal mini he 28 combi On and off

    Hi, hope I can get some help, boiler is fine for hot water, and rads get warm but not hot, calls for heat ignites and runs for about 90 secs then stops about 5 mins later ignites runs 90 secs and stops this seems to go on as a consistent cycle. Boiler lights don’t seem to indicate a fault code...
  7. gingalig

    Copper pipe in screed, unprotected

    Hi , I have just been asked to cap off a redundant supply to a no longer in use fire, I have spoken the customer on the phone and he tells me he has exposed some of the pipe work under the screed when removing the fire place, I asked if the pipework was protected or sheathed and what else it...
  8. gingalig

    Ultracom 38cxi Gas rate, gas flow on and off

    I hope it's ok, being posted here, I just did a gas rate on an Gloworm ultracom 38cxi, I put it into service mode Hi, and ran the hot tap in the kitchen, The meter was a metric and I timed for 2 mins, The flow of gas at the meter stopped, all be it briefly and then re-started twice during the...
  9. gingalig

    Meter spigot pipework badly sealed

    Hi, Sorry for posting the obvious to the more experienced of you, I've just come across a meter in a box with the gas pipe going out through the back via the spigot, The transporter had apparently come and changed the regulator a couple of weeks ago, my issue is that there is a lot of what looks...
  10. gingalig

    Looking at un-certified boiler ??

    I have recently passed my ACS and registered as Gas safe, I have been asked to check an install of a combi that was never certified , Apparently it was fitted by a gas engineer that didnt benchmark it. Any advice ? I was going to check , location ( for vents, ducts, etc ,correct fitting ), pipe...