Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. G

    Warmsafe plumbing and heating spares Preston

    Anyone used this firm for parts, are they genuine / reliable?
  2. G

    Landlord inspection heat input and bp

    Just wondering what other engineers views are with regard to checking the heat input and burner pressure on landlord safety inspections. The guidance tells us to verify the heat input and/or operating pressure of the appliance, however in a lot of cases the actual appliance kw data is not to...
  3. G

    Horizontal flue on sloping roof

    Been to a breakdown job with this type of flue, this one is reading very high combustion products after fitting a new gas valve. Looks like there must be a bad seal in the flue system as co is being drawn in with the air supply. Anyway, I have been asked to quote on repairing or replacing the...
  4. G

    Condense connection to rainwater downpipe

    Just looking for any suggestions, can't find a 68mm strap on boss and didn't really want to drill a hole and silicone. Anyone tried one of those mechanical soil bosses?
  5. G

    Prv on flow or return does it matter?

    Just wondered if anybody has an opinion as to why some manufacturers ask for the prv on a sealed system to be installed on the flow pipework rather than the return?
  6. G

    Thermal store with immersion only

    Had to cap off a manky keston celcius / uv spa combo due to flue leaking in void. Basically looking into alternatives to installing a new combi and having to rip out ceiligs etc to fit new flue and air pipes as current set is fitted within internal compartment. Done a few in the past and are...
  7. G

    Black 40mm compression waste fittings

    Why is it impossible to get hold of these or am I not looking hard enough?
  8. G

    2 port on UV cyl return

    Any thoughts on putting a 2 port on a megaflo return, which has a 3 port only set up. There is no room or pipework space to get it on the flow to cyl after the 3 port. Whoever fitted it must have thought the 2 port was a billy bonus for stock. My thinking is better on return than not at all.
  9. G

    Hallway radiator sizing

    when calculating the correct output for a hallway rad would you measure the hallway and landing separate and add them together as one room or would you just measure up the hallway? I went onto a couple of rad sizing websites and they give you options to select for different room types and they...
  10. G

    magnaclean on top entry boiler

    Installing a heat only boiler yesterday and came unstuck when fitting magnaclean to top entry pipework. They seem to only be designed for bottom entry boilers with the return inlet at the bottom of the filter and outlet to boiler at the top. It was impossible to configure the pipework to have...