Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. Kewat66

    Worcester Greenstar Highflow 440 intermittent hot water

    Hi All, Anyone come across this problem on the Highflow 440. Customer calls and says hot water not working. Sometimes only comes on with heating. I pop out to take a look and all working fine. New call 3 weeks later same problem. Again pop out but when I get there reset boiler and working fine...
  2. Kewat66

    Sime Planet 25/60 BF loud noise

    Hi All, i have been asked to look at a Sime Planet 25/60. This is a boiler I haven't seen before so I was wondering if any one nos of this model and if so recognise th se symptoms. When the boiler comes on in the morning it sound like a jet taking off, it runs for about 5 mins on heat the stops...
  3. Kewat66

    Ideal Logic 30 L2 code

    Hi All, i have an issue with Logic 30. Keeps coming up with L2 fault code. Have checked gas pressure, cleaned out condensate and still no joy. It runs through the sequence but will not fire. Anyone know of any simple or common faults on these? Thanks kewat66
  4. Kewat66

    British Gas 532i losing pressure

    Hi All, i have been working on a British Gas 532i ( Worcester with BG badge ) boiler kept losing pressure. Checked the pressure in the vessel and noting showing so re-pressurised to 1 bar. Called back next day as pressure dropped to zero on gauge. So I changed the vessel & prv. Refilled system...
  5. Kewat66

    Worcester 24i issue

    Hi All, i appear to have a problem with this Worcester 24i. About 6 weeks ago there was a problem with the pressure dropping and 2 leaking valves. These were all changed and all fine. I was called back on Friday saying heating was working, hot water intermittent. Customer said he has not topped...
  6. Kewat66

    Worcester R25 HE combi AE code

    Hi All, i recently carried out a gas safety on a Worcester R25 HE and all appeared fine. Next morning the customer has stated that the boiler is now running intermittently on heating for about 5 mins then an AE code appears. Reset the boiler and same thing happens. No problems on hot water. I...
  7. Kewat66

    Vokera Compact 25he Cuts out on heating?

    Hi All, i have vokera compact 25 that was not working at all. Had a good look at it and it ran with the cover off but not on. Diagnosed it as a Venturi. Replaced this and thought problem solved. Now the boiler works great on DHW but lights for about 10 seconds, then stops for 3 minutes, then...
  8. Kewat66

    Worcester CDI U Codes

    Hi All, i have been working on a Worcester 35 CDI. The boiler wasn't getting the heat away and was going up to 99 on the screen and then going into u codes. Nothing in the manual on these but having changed the pump, diverter motor & temp sensor the boiler worked for a week then started playing...
  9. Kewat66

    Main Combi 30 HE tripping the fuse board

    Hi All, i am looking at a Main 30 HE combi that is struggling to get going. It does after a few attempts fire up but as soon as it gets going and lights the burner the main rcd on the consumer unit trips. I am looking at changing the board. Has anyone had anything like this before and if so what...
  10. Kewat66

    Potterton Promax 15/2 HE Plus tripping out

    Hi All, i have a potterton promax 15/2 HE plus that keeps tripping out. Press the reset and the boiler lasts for about 2 days. I going back to it but because of the design the fault light sequence can only been seen with the cover removed and due to timing of getting back and the client pressing...
  11. Kewat66

    Radiators pumping out heat when boiler is off?

    Hi All, i have a Worcester boiler connected to 2 small cylinders. I am turning the boiler off but the rads are still red hot hours after. The programmer is only used for the heating so the hot water appears to be controlled by the stats on the cylinders. I am thinking that may be the motorised...
  12. Kewat66

    Vaillant Turbomax Plus 828e F60 Fault

    Hi all, I was asked to attend a faulty boiler. Turbomax Plus 828e. When i arrived customer said boiler has been working fine then stopped. Customer said fault code showing was F60 and according to manual states 'electronic defect'. He switched the boiler off and back on and then there was noting...
  13. Kewat66

    Ideal ISAR M30100 flame going out

    Hi All, i am looking at a fault on an ISAR M30100. Boiler fires up ok but after a few hours it goes out and comes up with an LF code. I am thinking of changing the flame sensor as it seems similar to the manual suggestion but this states the boiler goes out after 10 seconds. Is there anything...
  14. Kewat66

    Glow worm 30CXI F1 fault code

    Hi All, Attended a breakdown today on Glowworm 30CXI. Boiler started to go through the start up sequence, when igniting I was getting a spark for 1 second or so then boiler went into lockout and F1 code appeared. The manual stated gas supply, igniter issues etc. I have checked the gas supply to...
  15. Kewat66

    G10 Meter

    Connecting onto a G10 meter with 22mm replacing a combi boiler with a water heater in 15mm. I don't have commercial but the installation size is within domestic limits. Can I install this? Do I test the meter as normal (the regulator has 2 test points?)
  16. Kewat66

    Vailant ecotec plus 824 f75

    Hi All, looking at a vaillant ecotec plus 824. It is coming up with f75. This seems to relate to low pressure and pressure sensor. Have changed the pressure sensor, checked the pump, change the divertor valve ( that was original fault). System pressure is 1.5 and still no joy. Hot water fine...
  17. Kewat66

    Worscester 28cdi hot water noise

    Hi All, i am am looking at a Worcester 28cdi. Everything works fine but when the hot water is turned off after 5 mins or so there is a delayed clunking taking place inside the boiler. I am thinking it is something to do with the diverter valve moving back to position? Any other thoughts? thanks...
  18. Kewat66

    Glowworm cxi hot water then nothing

    Hi All, Trying to resolve a problem on a glowworm 38 CX I. Turn on hot water runs for about 30 seconds then goes cold. I am thinking because is the flow sensor? Reason I am thinking this is there is no fault code and there is no reduction in the amount of water coming out hence why I am not look...
  19. Kewat66

    'Servowarm' hot water/heating progressive manual switch

    Hi All, I am swapping over an old baxi boiler & cylinder for a new combi boiler. Whilst removing the cylinder i a have come across a Servowarm manual valve. I believe that this is a progressive valve that was used a few times of the year but i am confused as to what is is doing. The hot water...
  20. Kewat66

    Gledhill Gulf Stream A Class 12 Service

    Hi, I have been asked to carry out a service on a Gulf Stream A Class 12 and starting this post for any advise. Customer said BG wouldn't service or cover this on there annual scheme so alarm bells started. As this is the first one of these I have come across I was wondering is it an age thing...