Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. F

    Eco Max pro heat only

    Having a bit of an issue with above boiler. Boiler fires up till reaches 40-50 degrees then it just stops, no fault code. Seems like it's not modulating. Turned it off and on again and it does the same thing. Can anyone shed any light? Cheers
  2. F

    Baxi solo 3 pf

    Boiler fires up for 5 min then pump keep running for long time then randomly fires up again. Flow pipe only gets warm not hot. New pump has been changed thinking is circulation issue. Powerflush or new Pcb???
  3. F

    Baxi Bermuda inset 3 boiler lockout

    Boiler goes straight to lockout , red light not flushing, no spark, 240v at switch live. PCB seems good. Any help would be appreciated. Cheers
  4. F

    Greenstar 28 I junior ignition lockout

    Hi guys , having an issue with the "great" greenstar . Basically it does try to fire up, u can hear the spark clicking , it does try few times then it goes to lockout.(flushing lights) Checked the gas valve , condensing trap , can't check the ratio .before I start striping out .. any suggestion...
  5. F

    Potterton performa28

    Hi guys, working on above boiler, fan not running , flushing red under the fan sign. Fan spins freely , no power going to the fan. Any ideas? Cheers :santa_smiley:
  6. F

    Potterton performa 30he

    I'm loving these potterton/baxi faults with little bit help from guys in this forum. Working on potterton performa 30 he, ignition lockout. It does spark, inlet pressure ok, 4.1koms on gas valve, I'm thinking is the igniter plug on gas valve??? Any suggestion?? Cheers
  7. F

    Baxi combi instant 80 he , no hot water

    Working on Baxi combi instant 80 he, it works on heating but not hot water. New diverter valve and new plate heat exchanger installed by another engineer still no hot water. Can anyone shed any light?
  8. F

    Vaillant turbomax plus 828e blowing fuse.

    Hello guys, I've the same issue with turbomax plus in two different properties. Basically costumers left the boiler off while they been away for few days, they've come back , turned the boiler on and the boiler keeps blowing fuses on the PCB. Has anyone come across this before? Cheers
  9. F

    Potterton promax SL making a humming sound.

    Hi guys, having a problem with a potterton promax SL making a humming /vibrating noises. Gas ratio & inlet pressure it's fine. Has anyone come across this issue before. Cheers in advance.
  10. F

    Glow worm Cxi F5

    Hi guys, any advice on the above boiler with F5 error? I understand its overheating. Apart from resetting the overheat button, checking the pump , sludge on the system is any common fault on this boiler? Thx in advance.
  11. F

    Worcester 240 RSF

    Hello guys, having an issue with Worcester 240. It's overheating when u run a shower, it cuts out and needs to be reset. Thinking it's the the water to water heat exchanger partially blocked? Any ideas? Cheers
  12. F

    Glow worm 24ci not filling up

    Hi guys, apparently the filling loop on glow worms are prone to fail. Has anyone come across this? What's the remedy? Any help would be much appreciated . Cheers
  13. F

    Potterton profile 60e won't start.

    Hi guys,having a bit of issue with profile 60e. Basically so far I've checked the reset button , 240v going to the boiler, no power to the pump and fan, checked the external controls. Apparently the costumer had reset the boiler quite often for the past year. Seems like some overheating issues...
  14. F

    Ariston ACO 27MFFI

    Hi, having an issue with Ariston aco 27mffi. Basically costumers complains about some loud noises on the boiler but I haven't been able to catch while I'm there. It does only when the heating is on. So far I've checked the fan, ignition electrode , also the ratio on maximum and minimum input...
  15. F

    Ariston ACO 27MFFI

    Hi, having an issue with Ariston aco 27mffi. Basically costumers complains about some loud noises on the boiler but I haven't been able to catch while I'm there. It does only when the heating is on. So far I've checked the fan, ignition electrode , also the ratio on maximum and minimum input...
  16. F

    2 zone valve heating system , wiring advice needed

    Hi guys , I need a bit of advice on wiring a S plan 2 zone valve heating only. Basically it's a Remeha 30s , the boiler is used for heating only. The costumer want to controll the zones separately by 2 wireless room thermostats. I suppose it's not that different from normal s plan but I just...
  17. F

    Combi 24 i Junior problem?

    Hi guys, having a bit of issue with combi Worcester 24 I junior ,basically following the ignition sequences it clicks but won't start and it goes to lockout but it does start with the case off. I've changed the fan and APS and it was working fine. Then the next day costumer saying is going to...
  18. F

    Greenstar 28i junior

    Hello guys, working on greenstar 28i junior, got no heating but hot water is ok. After checking the roomstat I'm suspecting is the diverter valve. Is it worth changin just the divert valve motor or the diverter valve assembly? Any suggestion will be much appreciated.
  19. F