Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. T

    Firebird Condensing Boiler

    Firstly I don't install boilers, I'm not a plumber, I commission, service and repair, hopefully anyway. Was called out to a Firebird Enviromax Condensing Boiler after it had sooted up. Boiler is about 3 or 4 years old. Cleaned it out, changed nozzle, checked oil pressure. Still burning black...
  2. T

    High limit stat tripping on a warmflow oil boiler

    Good evening, about 2 years ago a customers high limit stat was tripping every so ofte,n not a sealed system. I turned the circulating pump speed up to 3 from 2 and seemed to cure it , until recently. Tripping again and hes now saying when he turned the Boiler on didn't heat water but rads were...
  3. T

    Firebird Low Box Boiler

    Good evening do any of you have any experience of the new firebird low nox boilers with eclo. Never seen 1 before but went to commission it. The co2 is meant to be 12.5 with a conventional flue. This boiler had a balanced flue with a plume kit fitted and the top bend that points the plume away...
  4. T

    The Gok oil priming pump

    I'm looking a oil priming pump for difficult air locks after a customer runs out of oil, new work etc. Is the Gok oil priming pump the 1 to get or is there anything else suitable out there, many thanks.
  5. T

    Pump or stat

    Hi can anyone please help with a control issue I'm not sure about. Old system no motorized valves or wall stat, just a pipe stat at hotpress. 1 circulating pump for oil boiler and fire. Boiler fires up NP but only for 5 to 10 mins so I thought pump. Householder checked for vibration when boiler...
  6. T

    Warmflow condensing utility boiler

    I was servicing a warmflow condensing utility boiler today . It must be in about 6 years as its dated sep 2009. Its right tight to the wall at the left hand side with no pipework at that side. Seems a little damp low down and u can feel it off the jacket. Isnt the drain down valve either. It is...
  7. T

    Wood pellet boiler

    Just wondering what yous guys think of wood pellet boilers and if they are worthwhile as far as running costs , effeciency, reliability and do they heat as good as oil does. I know someone who has a old oil boiler that needs replaced and has possibly been offered a wood pellet boiler for free...
  8. T

    Room stat

    Hi ive quite a bit of experience in servicing and fixing oil boilers as i have in the past done my oftec 101.I also have a oil pressure gague and a kane 250. My problem however is with the heating controls.I have not been out to the house but the boiler was firing but no heat in rads.He took...
  9. T

    high limit stat

    Hi was just looking a second opinion on a job ive to look at. Its a old grant 50/70 euroflame. Its on an open vent system with no stats inside house. The high limit stat trips most days not while its in its cycle . Im told it wotks ok then just trips out after it switches off at time clock. I...
  10. T

    boiler not firing up or locking out

    hi can anyone tell me what the fault would be in a boiler ive been looking at.its already had the transformer replaced and is firing again.but now when it kicks back in again on stat it doesn't fire up or lockout just blows cold air,im thinking control box or photocell.its a old boiler with a...
  11. T

    replacing the old danfoss bh012.1 control box

    Will try and post in the proper place now , can anyone tell me what replaces the old danfoss bh012.1 oil control box. I have a danfoss bh072.10, siemens loa24.171b2b and a landis gyr loa24.171b27 in my box ,any help would be appreciated.
  12. T

    flue gas analyser

    do any of the guys in n.ireland on here know anywhere local to get your fga calibrated.
  13. T

    warmfkow condensing boiler

    hi was wondering if anyone can help me with a problem im having with a riello rdb burner on a warflow condensing boiler i looked at today.it runs fine for anything from 10 mins to 20 mins then loses pressure from 9bar to zero.it then either relights or cycles on and off a bit but doesnt...