Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. J

    combi to system conversion

    WB 12/14 Heatslave can't cope with two showers so fitted an unvented HWC on S plan, but need to shut off hot water section of combi. Boiler engineer has visited and was going to do the work, but he does not respond now, not upset him that I am aware of. Can anyone advise on the process, is the...
  2. J

    Worcester Bosch Danesmoor 15-19, rads not heating up

    This installation dates from 2006 and is in my parents house to heat 10-12 rads but not hot water which is done by the AGA. They have the boiler turned on all the time and use the temperature dial to turn it on and off. It has got the seven day timer, but that is beyond my parents usually. So...
  3. J

    Extension heating options

    A single storey building in a L shape, I have planning permission to develop one leg of the L into accommodation. The other leg is accommodation (converted in 2005) as is a small part of the leg to develop, if that makes sense. There are two outbuildings to be converted and extended, by removing...
  4. J

    Cold Rad on an AGA cooker

    The bathroom rad is fed by the water from the AGA. The system is indirect feed to the hot water cylinder from the AGA and return. A pipe from the top of the hot water cylinder feed pipe goes into the loft and to the expansion tank. About 2 feet from the expansion tank is a T connection and the...
  5. J

    Cold Rad

    An oil fired boiler with the bathroom rad connected to it, but the rad does not heat up. Indirect system, the pipe for the expansion tank is taken off the top of the HWC feed and into the loft. In the loft is a T and the feed for the rad comes off the T. The return for the rad goes through the...
  6. J

    Hot water too hot

    The Aga on the ground floor supplies hot water to a hot water cyl on the ifrst floor. The HW cyl was 20 galls against a recommended 40 galls so the bathroom rad was added and connected to the AGA circuit to absorb some heat, this worked well. 4 years ago I installed a separate boiler and rads...
  7. J

    Dismantling toilet waste pipe?

    To be able to unsolder a pipe connection and to solder a new one I think I will have to remove the toilet waste first. In the shower room below the bathroom the bathroom waste comes down the corner of the shower room, behind the waste are the two 15mm pipes for the shower room basin, They...
  8. J

    old type toilet siphon

    This toilet is 30 years old, It has a tube protruding from the cistern into the bowl which I broke and there is the hemispherical piece of rubber with a hole in it that fits over the pipe. The new siphons seem to be simpler and I seem to recall that these old types are no made anymore, is...
  9. J

    Hot water leak and bloackage

    The oil AGA was not heating the water in the indirect hot water cyl (which I replaced on Wednesday), the feed pipe was barely warm. The AGA engineer suggested tieing the CWS tank ball valve up to see if there was a leak on the HW side which would explain why the AGA would not heat the hot...