Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. N

    24i RSF intermittent fault help

    Basically the boiler stops working intermittenty for heatingand water... It had a leak from auto air vent which was dripping into the APS which has been repaired.. Everything seems to be working I've tested the harness to the APS and the overheat stat. and out of desperation changed the PCB...
  2. N

    back boiler heating circulation issues

    I hope someone can help as its driving me round the bend. Its and open vented system with a baxi 552 back boiler. the water work perfectly but the heating flow pipes to the radiators get hot but there is no circulation . The flow pipe is hot to all the radiators but the return pipe is cold...
  3. N

    Baxi duotec showing DHW temperature as 90deg

    Been called to repair a baxi duotec 33he. The display is showing the Water temperature going up to 90deg and switching the burner off. until the temperture drops and fires up again...and keep going in this loop. The water is not that hot i put my hand under it its def not 90deg its about 60deg...
  4. N

    Worcester TR2 Alternative

    Is there an alternative thermostat that could be fitted instead of the TR2? The TR2 in my own house has started playing up. It had previously been working ok for 9years. All the wiring is ok Regards Nas
  5. N

    Ravenheat CSI 85 AAAT new install problems

    I fitted my first (and possibly the last) yesterday. But the boiler isnt working properly. It fires up for heating for about 10ses the pipe get v hot and it then cuts out. After checking everything I could think of i came to the conclusion its a problem with the pump as the problem seems to be a...
  6. N

    Ravenheat white star No hot water

    The heating works fine but no hot water . Ive changed the diaphragm in the diverter valve. And check the microswitch the on the diverter valve as well. According to ravenheat it could be the PCB if the microswitch was ok. Anyone have any experience of this boiler???
  7. N

    Wiring a y-plan system for a worcester greenstar 28he without capacitor

    Is there a way of wiring this boiler to a y-pan system so it does not require a capacitor on the switched live. I have wired it up but the heating will not switch off. After checking everything Im assuming it's because I've not got the capacitor in the circuit. Thanks in advance
  8. N

    Main Eco 30 Explosive ignition

    Installed this boiler last last week. Got a call back saying it's making a loud noise when starting up. I've checked eveything possible and the main engineer has been as well. he just put some additional insulation around the ignition electrodes, But the boiler still has the same problem. I've...
  9. N

    Which work trousers?

    Can anyone of you recomend a good pair of work trousers needs a new pair? Obviously looking for good value for money. Thanks
  10. N

    Heatline part number?

    Does anyonw know the part number for the red valve in the picture. Its on the return of the heating pipe. I need a new one cos red the lever has broke off in the closed position. (The picture is of the same valve on the flow side).
  11. N

    Potterton performa 30HE no hot water

    I've checked all the obvious the apart from the DHW temp sensor, can this cause the boiler no to fire when there is demand for hot water? The Heating works ok and the DHW diaphragm is ok , the only thing I didnt check was the DHW water temp sensor. The Assuming the PCB is I can't think of any...
  12. N

    Worcester 28i junior only fires up with the cover off.

    Does anyone have any experience of this boiler its the non condensing version. The boiler wasn't firing up so I took the cover off to check the APS and everything started working. I put the cover back on and it stopped workign again. The flue seems to be ok as does the fan, what causes this...
  13. N

    Anyone have any experience fitting A Biasi active a 35c

    Before I begin I must say this invloves the worst kind of customer. One who went against my advice and had the above boiler fitted by someone else to save £25. Now its come back to haunt him.. I've been called to look at this newly installed boiler. He complains it gives Err04. Which acccording...
  14. N

    Anyone installed a Worcester 37cdi?

    I'm in the middle of fitting one of these, Everything has gone ok apart from the PRV. How does the the plastic bottle under the PRV connect to it? Is it simply a loosening the nut and pushing it up? :confused5::confused5::confused5::confused5::confused5:
  15. N

    Worcester 25si not working afer service.. Help!

    I serviced the boiler and cleaned the heat exchanger replaced the gasket and now it wont fire up. The reset button is flashing but it does not reset. I've made sure the baffles are correctly inserted. I Noticed the White hose( similar to the one on the air pressure switch) not not connected to...
  16. N

    Intergas boiler

    Got to install one of these tomorrow. Just looking at the online manual how do you check the pressure of the heating system, when you're bleeding the rads?
  17. N

    Potterton puma 80e

    Anyone any experience of potterton puma 80e firing up by itself when the power switch is turned on. But if you open the hot water is gives red hot water, When the taps are turned off it goes to lock out. Thanks in advance
  18. N

    What component fails in an Ideal Isar/Icos PCB?

    I've got a couple of these now. One Is completely Dead and does not power up and the other Keeps the boiler running permanatley on. Does anyone know what components fail in these PCBs (they are the orange ones part number 174886)
  19. N

    Baxi 51/5 Back boiler manual

    Hi Can anyone tell me where I can find the MI for the baxi 51/5 backboiler. Thanks in advance
  20. N

    Ideal boiler part numbers

    I need the part number for a Ideal Isar boiler, the part is the drain valve (has a little tap under it), fitted to the return pipe. Does anyone know the part number for it? I tried to get the number from the Ideal website but they charge £15 for the privilege. There no way I'm paying them!!!!