Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    oxypilot problem on focal point fire

    i have an Ashleigh plus focal point gas fire , the pilot light only lights out of the hole that points onto the thermocouple , the hole that points to the gas burner under the coals doesnt light on ignition . This means the fire lights with a " woosh" when the gas finally ignites , and when the...
  2. D

    one cold rad

    one of my rads is not getting warm top or bottom , system only been in 3_4 years so dont think its sludge , its possibly the furthest from boiler and is downstairs ( boiler is upstairs ) could system need balancing ? i read somewhere that i should shut all other rads and see if it gets warm then...
  3. D

    Rads different temperature

    Some rads get very hot and some get warm .if I screw the lockshield valve in a little on the hottest ones ,will this make the warm ones get hotter ? Thanks
  4. D

    balancing radiators ?

    i have been reading about balancing and have an idea how to do it i just have a question about when you have to screw in the l/shield valve on the rad that gets hottest first . on my system , this would be the one in the bathroom that has two l/shield valves on as there is no trv on it , so...
  5. D

    lockshield valve leaking ?

    i have replaced a rad and when ive fitted new one , the lock shield at both sides ( its a bathroom rad , so doesnt have a trv ) are leaking via the spindle . if i try to pack them using ptfe tape , do i need to make sure there is no pressure in the system ? i have a combi boiler and pressure is...
  6. D

    Cold radiators

    Central heating system been in nearly 3 years .now all of a sudden a couple of radiators aren't warming up .Have bled them and it gets hot immediately after the trv but rad not getting hot .I don't think it's sludge as rads only been on 3 years .What else could it be ? Thanks