  1. king of pipes

    Glowworm hideaway service

    Not many of these left on my books but all in all in pretty good nick for 20 years + . Kop
  2. king of pipes

    Heat transfer fulid 12345678

    Anyone be used this stuff got give a free sample ?
  3. king of pipes

    Intergas rapid 30kw 2 years service

    First full strip on this rapid expansion vessel needed repressrising and system topping up other than that not missed a beat in 2 years house is nice and warm the customers bills have not increased so happy days. Cheers kop
  4. king of pipes

    Baxi duo 24kw Tec choked up

    Went to a Baxi duo Tec 24kw today plate heat exchanger was choked up with debris really bad and no hotwater , did my usual trip to the local car wash and power washed it out cost me £4 mind as took 2 goes , serviced the boiler and the expansion vessel recharged repaired a leak on the sensor all...
  5. king of pipes

    Valliant ecotec 37kw + Oso 210 unvented cylinder

    Nice little project all first fixed huge open plan living area kitchen , utility room , double bedroom , and cloakroom, all heated by underfloor heating. This is my first Oso and specifically went for it as all the connections are on the top of the cylinder and the space I had to work with was...
  6. king of pipes

    Valliant pure rear flue

    Anyone fitted these problem I am finding is it does not close down enough for the thickness of the wall and cannot be cut they are not the same as a normal horizontal flue , phoned Valliant technical they said it is what it is not alot of help. Kop
  7. king of pipes

    Chrome radiator tails

    Recently offered a customer the option in their open plan living area radiator you guessed it now doing the whole house anyone offer their customer a choice . Kop
  8. king of pipes

    Glowworm ultimate 24 hxi

    8 year old Glowworm serviced by me every year for the last 7 years still running sweet just shows the importance of good servicing . Kop
  9. king of pipes

    Ideal icos 6 years without a service

    Went to this boiler today as the property is being sold and the owners have had a offer , the boiler was nearly jumping off the wall when firing up:eek:💥, stripped it down to find the heat exchanger blocked solid with aluminium scale not allowing a smooth flow of products through bit of tlc and...
  10. king of pipes

    Valliant pure 15kw heat only on a s plan

    I will start a heating upgrade on Monday removing a old glowworm boiler and upgrading the system from a y plan to a s plan , new pump , twin channel programmer , room stat , auto bypass , new Trv's and lockshields, am I right in thinking I will need a pump overrun facility for this boiler all...
  11. king of pipes

    Greetings from a DIY hopeful

    Fire away a wealth of knowledge on here welcome. Kop
  12. king of pipes

    Tenerife flue !!!!

    Sorry chaps couldn't resist this one obviously no scaffolding or grinders here 😁 😁 kop
  13. king of pipes

    Atag one control

    Finally got shot of this God dam awful thermostat, now have a 3rd generation nest linked to a Google home smart speaker works a treat . Kop
  14. king of pipes

    Baxi net- tec 28 - 325 fault code ?

    Called out to this fault supposedly a low voltage problem , replaced the pcb now sorted .kop
  15. king of pipes

    Baxi 412 heat only

    First full strip down on this fitted 24 months ago now customers bills have come down significantly so all's good , could do with 3 hands on one of these but no dramas in the end .kop
  16. king of pipes

    Losing out on work lately ? ? ?

    Is anyone noticing that customers are tightening their belts a bit ? I have recently been beaten on price by other local tradesmen still winning more than I loose but they seem to be very competitive, not to worried for now but I would like you thoughts gentlemen . Cheers kop
  17. king of pipes

    Baxi 600 range of combis

    Finally got round to fitting one of these today Halstead ace out and Baxi 630 in , first impressions is not good, no jig ,new filling link is a faf to fit and s- ite design, commissioning it is a ball ache 7 minutes purge cycle not a lot of good when the fur kin pump is siezed grrr , so...
  18. king of pipes

    Boilermate replacement

    Been to 2 jobs today where I need to upgrade the heating and hot water both have boilermates fitted with potterton suprima boilers in the kitchen because of pipework layout still a bit unsure which way to go any suggestions chaps . Cheers kop
  19. king of pipes

    Valliant 631 37kw heat only f62 intermittent fault

    Digital Temperature read out jumping about a bit my diagnosis is PCB on it's way out any one had this . Kop
  20. king of pipes

    Advice needed on DIY central heating plan

    If only it was as simple as that JAT there a certain safety features that need installing with this type of system and as above you must comply with building regulations, you may by all means be able to do some work yourself but I would strongly advise you employ a HETAS engineer for the the...