  1. A

    Megaflo pressure reducing valve

    Hi everyone, Was called to a megaflo last night, no water coming from any taps. Followed the recharge instructions but made no difference. I heard gurgling but no discharge appeared and the gurgling stopped after approx 3 minutes. I spoke to heatrae sadia who recommended new pressure...
  2. A

    Wiring up bathroom fan from pull cord. Correct?

    Hi everyone, I have a bathroom fan to wire up tomorrow evening. I have had a look through the instructions but wanted to double check a few things. The fan has no timer just a neutral and live. The light pull cord has just L1 and com and earth connections so can I use this? I am fitting...
  3. A

    Sealed system powerflushed and balanced. Not working

    I'm going to look at a job tonight, Customer called yesterday and said she has had it powerflushed and rebalanced but the heating does not work. She said sometimes one or two rads will warm up sometimes nothing. She said she has added a couple of rads to the system. Apparently someone has...
  4. A

    28i jr turned on for llgsc doesn't work

    Hi guys Went to do a landlords gas check last night. Boiler was off at the wall, tenant in the middle of moving in. She said the boilers been switched off for approx 3-4 weeks since the last tenant moved out. I switched it on, blue light illuminated for power straight away. Created a demand...
  5. A

    Siamp flush valve only gives short flush.

    Was asked to have a look at a few things for a customer this evening. Sink waste needs altering so the washing machine doesnt back up and, a new shower and an issue with the toilets. x4 close coupled toilets in the property. All with Siamp flush valves. 2 of them work as they should, long...
  6. A

    Potterton performa fan fault

    Hi everyone, I am going to look at a performa this evening. The customer called this morning, said its showing fan fault and he's 'narrowed it down to pcb or fan'. Sounds like he is going to be great, he has wired up loads of boilers apparently. What checks can I do to test the components...
  7. A

    35cdi hw only when ch on. Since power cut.

    Hi everyone Got a 35cdi to look at tonight, Customer said they had a power cut and ever since the hw hasn't worked unless ch is on. Is this likely to be a coincidence and should I be looking at the diaphragm? Or something else? Thanks
  8. A

    Bath/shower diverter washers

    Hi does anyone know where the best place to find a selection of diverter washers/seals for Bath shower mixers? Been asked to repair one, it's old and really needs replacing but the taps are fine it's just the diverter seal has perished. It's a horrible tap change and would be the difference...
  9. A

    Replace this shower. The bigger the concealing plate the better.

    Need to replace this shower. House is being sold in a few months so Cust wants minimum disruption to tiles. There is a towel cupboard behind the shower with a shelf that I'm going to have to cut out to access the shower. There is a panel covering the pipework for the head that I can remove...
  10. A

    Ideal icos leaking from sump plate

    Hi Went to look at an icos tonight, all working fine but leaking from the sump plate. Codense run internal, probably 4m long. Joined to the kitchen waste. I cut the condense under the sink and it jetted out and was black and warm. Cleared blockage, reconnected. Checked trap all clear...
  11. A

    Replace a Potterton kingfisher

    Evening, Been to look at a Potterton Kingfisher tonight. Customer has stripped all the casing off looking for a leak. They said after running, radiators will start to heat up then the boiler cuts out and water appears on the floor. They have lived there for 35 years and the boiler was in...
  12. A

    Baxi 105e diverter issue

    Cust has sent me this picture. Dont ask me why he is taking the case off the boiler and messing with it. On the diverter valve the pin in the photo does not hit the microswitch, Cust activates the microswitch himself and boiler will work fine. This would mean the diaphragm needs replacing...
  13. A

    Salamander pump comes on and off when basin tapused.

    Hi Property has a Salamnder pump. It does the shower which is on the same level and does the bathroom upstairs. The basin mixer tap in the same room as the pump, hot does not come from the pump, cold is mains. Same for the kitchen. When the hot is used on the basin or kitchen the pump will...
  14. A

    Remeha avanta e10 fault

    Mate of mine has just text. I cant get there because im busy but their remeha avanta plus 24c is giving e10 code. Started off e5. Condense was frozen. They have bled rads said I will get up tonight is anyone familiar with whats happening? Thanks
  15. A

    Following BG powerflush rads still not getting hot.

    Elderly customer with a 10 rad system. Last 2 rads on system (downstairs) were not getting hot at all. Has contract with BG, they came round, turned off some rads upstairs and downstairs all got hot but said needs powerflush and new pump. Powerflush carried out then rads were worse. Most not...
  16. A

    Change alpha 2 pump settings

    Hi Cust has a new alpha 2 pump recently fitted. Seems to be set on speed 1. I cant seem to alter the speed. Not fitted by me. Buttons on front dont do anything. Any ideas? Faulty pump??
  17. A

    1000mm ideal flue stockist?

    Anyone know where I'm most likely to be able to get a 1000mm ideal flue tomorrow? Thanks.
  18. A

    Britony combi se 40 80 flashing

    Hi Ok went out to have a look at a mates boiler a couple weeks ago, he said he wants a new boiler. Ex vessel has gone but also numerous leaks and never been serviced. Managed to get it running, said to him give me a weeks notice and I'll replace it. Did I hear back? Course not. Text tonight...
  19. A

    Plastic isolation valve. Which brand?

    Did a cistern strip down for someone yesterday. Said now not flush (Button has popped off) sent me a photo of isolation valve which is now leaking, what make is it? Needs to be a straight swap just for time and ease. Going back this morning. Thanks
  20. A

    ID or AR on this flue?

    Serviced boiler tonight. This is the flue outside. It meets the 300 to the window to the mm pretty much. This rubber collar is supposed to be on the outside of the wall. It's inside the wall. fga readings were fine after I had to adjust co/co2 as per mi's. Couldn't TT as where the test...