  1. A

    Replace rad and chase pipes in wall.

    Customer wants this rad replaced and the pipes chased in to the wall. Pipe is very close to the switches but can be moved over slightly to get away from the cables. What do you reckon? Worth doing? Will have to cover the pipes I know to protect them. I have said to the customer that I will...
  2. A

    Request to move gas meter

    Hi everyone, happy new year. I Hope you all had a good christmas. I have received an email from a cust asking me to move their gas meter. Less than a meter apparently. From a larder cupboard to an outside wall. The gas supplier would have to repipe the supply and move the meter I know but...
  3. A

    Leak from tf1 filter

    A few weeks ago I was called out, every morning the customer gets up and there is a pool of water on the floor. When I went no leak to be found. Tied some blue roll round the tf1 valves, told them to keep an eye on it. Next morning, blue roll on the valves was wet and water on the floor. I went...
  4. A

    Underfloor heating, 1 side not working.

    I have to look at a job tomorrow. The cust called and said that one side of the room works fine but the other side doesn't work at all. Reckons 1 half hasn't been connected up. Sounds a bit strange, I asked if it's always been like that and he said yes. Installed approx 1 yr ago. Also said he...
  5. A

    Landlord gas cert pricing?

    Hi, I understand some people don't like discussing money or giving away their prices so I understand if I don't get many replies. If you don't mind sharing, what do you charge for a Landlord gas safety cert? I have had people say they need a few doing soon but not sure what to charge them...
  6. A

    Flamco pressure reducing valve

    This is a pressure reducing valve correct?
  7. A

    Baxi combi pressure issue

    Looking at a baxi combi tonight. Pressure drops to 0.2 but will go up quite high when running on CH. Needs repressurising regularly. I don't have a lot of info yet but what could cause this? I'm going to check prv and ex vessel anything else I should look at? Thanks
  8. A

    Potterton suprima not working

    Hi, Went to service a suprima, it's not working. If put on a demand for Ch or hw, you hear a 'click' at the boiler, no sparking, fan does not run, the pump will spin for a second and stops. Voltage drops in and out. Had a new PCb 6 years ago. Customer said this has been happening since he...
  9. A

    Hive installation easy?

    Just had a neighbour ask me if I can pop in tomorrow night to fit his hive controls, I've never fitted hive before, is it straight forward? He spoke to me at my door and said something about not having a neutral, won't know what he means until I have a look. Obviously customer will need...
  10. A

    Chrome radiator recommendations, not towel warmer.

    Hi, Have a cust who wants a price to supply and fit a chrome radiator in their bathroom. Only 2.5m x 2.5m room. Does not want a towel warmer as do not give out much heat. Approx 400w x 1000h ish. Can anyone recommend a decent supplier/brand? Thanks
  11. A

    Bristan bar shower. Luke warm

    Hi Newly installed Bristan bar shower, hot comes out lukewarm only. Have set the cartridge to hottest setting, makes no difference. In before was a bath shower mixer. It's a town house, shower on middle floor, cylinder on top floor if it matters. Is there anything I can do to increase the...
  12. A

    Shower tray next to window. Enclosure options?

    Hi everyone Started a job today, bath out and put in tray. I've advised against it but cust adamant. The tray is going in the corner but there is no where to fix an enclosure along one side because there is a window there. I explained all this to them, even if I was to put an enclosure in...
  13. A

    24 RI CH comes on when water on. Possible programmer fault also

    Hi everyone Been a while, hope everyone is well. Been to a job tonight, if hw on rads get hot also. Ch 2 port seized open. Lever on valve permanently slack. 24 RI Another issue seems to be programmer might be working intermittently. Even with ch and hw turned off at programmer, boiler fired...
  14. A

    Potterton Suprima. Runs for few hours then shuts down, red light.

    Hi Potterton Suprima I have to look at, red flashing light. Will not reset on button. if it's switched off at the wall then switched back on it fires up fine and will run for a few hours no problem. Goes off again, will not relight. What would you be checking? I'm thinking slow running...
  15. A

    Fitting wall hung gas fire after Bermuda removal

    Hi cust wants new wall hung gas fire once his boiler is done, I've told him let me sort boiler then once back boiler and fire is gone I'll have a look. money is definitely an issue now he is having the boiler done. Anyone fitted a fire after removing a back boiler? Any advice on best way to go...
  16. A

    Baxi Bermuda to Combi change.

    Ok I've started this thread to add some pictures and show what I intend to do. All advice welcome, I don't pretend to know everything and if anyone spots something they think is incorrect let me know. first of all, can I confirm this is correct: this is the flow and return coming from the...
  17. A

    Baxi bermuda pw3. Help on job now

    Pilot is alight Pump is running Mains burner lit for short period then goes out Any ideas? Thermocouple it gas valve I'm thinking.
  18. A

    Ideal logic 30 combi. HW issue

    Hi, tonight's job is as follows. Cust has just bought the house and not moved in yet, currently decorating. Been to look at their ideal logic 30. Boiler in the kitchen. Shower is a thermostatic bar. Water runs Luke warm. Basin runs a bit better but runs cooler the higher the flow. Bath hot tap...
  19. A

    Basin taps need revivers but standard ones are too short

    Hi guys need some info for a friend please. Basin taps need new revivers, taken old cartridge out but when he put new ones in they just turn and turn, do not shut the water off. Tried another set with spacers to make deeper which work but keep coming apart, after a week. These are just the...
  20. A

    Toilet not clearing, flushing ok, can't find blockage.

    Last job today, the girl says the toilet isn't clearing properly. I flushed it with nothing in the pan to see if it backed up, the water seemed to swirl around the pan unusually but went away, a bit slow going down but couldn't say it backed up. I put some tissue down flushed it, didn't clear...