Search results | Page 7

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. A

    Ariston primo 150 immersion

    Hi guys Need to change the economy 7 immersion on this cylinder Assuming it will only take a straight swap. Anyone familiar with these are they fitted the same as a normal immersion?
  2. A

    How to confirm blocked cold feed?

    Any tips? i went to job the other week, someone had been out and said Cust had a blocked cold feed. It was correct but the customer said engineer didn't test anything he just knew. What's the best way to detect this what tests can I do?
  3. A

    28cdi combi with f and e

    Hi guys, been out to this boiler, it's a combi but it's not a sealed system it's tank fed. never seen this before. customer has complained that hw is intermittent. Colleague of mine has said change the plate. I'm not entirely convinced, went through fault finding, checking pressures and...
  4. A

    Ideal logic 24 hw flow terrible

    Hi guys had this boiler tonight. Hw pressure is terrible at all outlets. Cold is fine. had a bit of orangey water come out the bath taps. Stopcock has been off to change a scale reducer on mains up to boiler in the loft. Not by me. Cust is an idiot, trying to tell me where there is a...
  5. A

    Basic megaflo compact. Strange issues, no hw.

    Went to this job today and was there quite a while, it's a baxi boiler, unvented cylinder upstairs. I get get there, boiler works fine on ch, put how to constant nothing, light comes on at programmer but no 'click' sound. So quick job swap programmer over - no change. but if I turn he to...
  6. A

    Ideal he 30 espirit. He ok ch runs for 20 seconds

    Had customer from hell today. insurance job, no proof that boiler has been serviced so not covered. already wasted time investigating before I found this out. she was crying, saying husband just died, she has heart problems. Can't afford to use the electric fire. Grrrrr. anyway, ideal he30...
  7. A

    Sime combi fuse keeps blowing

    Went to this boiler yesterday, 240 at the board coming in. 2amp fuse had blown. replaced the fuse, it blew again the second we switched it on. Back there tomorrow with a load of 2 amp fuses and have a new pcb just in case. I have been advised to unplug the different components until the...
  8. A

    Wireless room stat for 30 CDI Classic

    Can anyone tell me what wireless controls I can use on this boiler please. Unvented cylinder if that makes a difference. Programmer downstairs. No room stat anywhere. Can i get a salus or worcester plug in the front types? Thanks
  9. A

    First time fitting a cold water tank tomorrow. Some questions

    Hi guys Fitting a 25 cold water tank tomorrow, taking out an old metal tank which looks as thought it is insulated with slabs of straw/hay. She had a leak in the loft last week, i went to investigate, obvious signs of water in the loft, metal tank with lots of rust inside and out. Time for a...
  10. A

    Anyone familiar with Honeywell Smart Fit?

    Went to a job today and they had no HW/CH, fault code at the Smartfit programmer showed the fault F 03 which is the actuator. Picking one up in the morning, does anyone know if these are removable head type actuators? Hoping it is as will mean I can get the job done quicker and have more...
  11. A

    Lockshield size

    Hi guya had a job yesterday that could't be completed. 2 lockshields needed changing, it's small pipe. I had 2 10mm lockshields on and these were too big. Can't seem to find smaller, anyone know where i might get some?
  12. A

    Dodgy Pump symptoms?

    Went to this job tonight. Reports of no hw and no ch. All turned off on programmer, i switched on hw and it fired up. CH going on and off as it should, on auto and constant. These scenarios do my head in, turning up to a job and everything is working - how can you fix what isn't broken...
  13. A

    Kitchen mixer back nut. What spanner, not one of the little ones.

    Hi got sent to change some taps the other day, normal looking kitchen mixer except for the back nut. I know it's not something that is really unusual but what size is it, need to get a back nut spanner for it.
  14. A

    Alpha 240p first no HW now nothing. Parts changed.

    Hi guys I got asked to go and have a look at a job yesterday for the above boiler. At first they had no HW so someone went and put in a new plate heat exchanger. Still didn't work, someone went and changed diverter valve (i think). Still didn't work, they ordered a PCB and lucky me got told...
  15. A

    Familiar with Barlo 2 port valves?

    Been to a job, someone had been before me and changed a pump but still no hw. Customer hadn't turned heating on yet this year. I pushed lever on 2 port and it all fired up. Switched heating on appears to work ok. Turned both off at programmer, everything still runs. Removed programmer...
  16. A

    Potterton profile, ch works ok. hw works but rads get hot also.

    Going to this job tomorrow. The central heating works ok, goes on on and off when it should. The boiler fires ok when there is a demand for HW but then the rads get hot too. Apparently it's had a brand new three port put in last week but the fault still continues. Programmer? What else...
  17. A

    Heatrae sadia Immersion thread???!!!

    Ok got sent to a job today. Horizontal cylinder in the loft, leaking from immersion and going through the ceiling in to the room below. Someone had already been and told me i need a 27inch standard immersion, picked one up this morning and went to the job. Drained the cylinder and removed old...
  18. A

    Potterton profile 50. Attempts to light over and over, burner momentarily lights

    Hi guys Went out to the above job today, turned out to be a waste of time as one of our lads already went out Saturday night and turned it off and has a part on order. The symptoms are if you switch either ch or hw on at programmer, the boiler attempts to light. You can see the flames then it...
  19. A

    What is this cistern?

    This needs swapping like for like. It has been leaking and damaged her floorboards. An engineer went out before me and all he did was isolate and tell her it needs a new cistern. It doesn't need a new cistern, the fill valve needed adjusting as it was filling with enough pressure that water...
  20. A

    can you identify this flush valve/siphon?

    Any ideas? I can't read what the brand name is in the first picture. Can't find it on google. Excuse Skeletors hand in the picture.
Back
Top