Search results | Page 4

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. townfanjon

    Baxi Brazila

    Gents, on this job this morning, please give me your thoughts .... customer is considering a new Brazila . The problem his house sits slightly forward than his neighbours ,so the flue is over his neighbours path. Theres nothing near it , as far as i know it is ok as a existing installation...
  2. townfanjon

    Boiler not registered

    Morning gents, can anybody help me with this one .... customer moved into a new developed property at Xmas , the heating system was described as brand new ( I have seen the agents brochure ) Lots of problems but the main one is , the brand new boiler was manufactured in 2008 ( WB junior ) I...
  3. townfanjon

    Heat loss calcs

    Gents, do any of you use the mr combi heat loss calc apps ? i recently downloaded them to my I-pad, I have just done a calc using the app , and for the room in question I ended up needing 1800 watts, I knows it's a very quick basic one but it sounded a lot so I calculated it long hand like we...
  4. townfanjon

    Power flushers

    Gents, any advice would be grateful. i have been lucky up until now , I have never bought a power flusher, I have borrowed my pals .he's now moved an extra 45 mins away , bit ignorant I think , but there you go , he has to now buy a freeze machine because he used to borrow mine LOL I am just a...
  5. townfanjon

    Log burner

    Gents, could somebody put mu mind at rest with this one lol in the TFJ household last night, log burners on like most evenings, and has been for the last 12 ish years. I put on a log which was defo a hardwood one, 30 mins later I considered ringing the fire brigade , the fire was beyond hot ...
  6. townfanjon

    boilers knact, the bath hot is not hot enough !!!!

    first one of the winter for me, customer has already remarked the bath hot is not as warm as the basin hot. (usual combi winter problem) I would normally try fit one of the wondervalves (the ones with the coloured cartridges to suit the amount of water required) but on this job some MORON has...
  7. townfanjon

    logic losing pressure

    Ehup chaps, I can't believe I am posting this. 3 year old logic, my daughters and her chaps ( sorry he's a sparks ) i went round on sat afternoon , depressurised system, checked and topped up ex vessel , repressurised. hes topped it up twice since , there's no sign of a leak anywhere , he can...
  8. townfanjon

    old honeywell trv

    just a long shot chaps, my customers dog has just eaten his TRV , (16 week old bull terrier) its the old Honeywell type , I think its a T 100, has anybody got one on a shelf in the garage they want to sell. Thank you
  9. townfanjon

    Dudley cistern

    Ehup guys , anybody out there know where I can get a fill valve ( turbo master)for their concealed cistern. I have tried the regular 3 merchants I use with no joy . thank you
  10. townfanjon

    anyliser service

    the old Anton is well overdue a service, it generally goes back to Anton but I have never liked posting it. Does anybody know anybody in the Yorkshire area who would service / calibrate it. Otherwise can anybody recommend reliable company to send it to. Thanks guys
  11. townfanjon

    Effin Baxi's

    help please guys Baxi gold combi 28 KW, I fitted it 4 years ago , (I have done the previous 3) just gone to service it this morning. Gas off, lecki off, burner/fan out, everything disconnected with care. Trap bowl cleaned. All put back, and I get E1- 33 (interrupted gas supply) reset and keeps...
  12. townfanjon

    thermal store

    gents, this is probably worth a punt. Does anybody know of a thermal store cylinder(150 litre) that has nt got the sprayed on insulation on show i.e the customer wants to look at a shiny white case. The only one I know of is the mega bucks elson aquanox. I would nt entertain a pullsar coil...
  13. townfanjon

    Diyers on plastic!!

    I am with you on this Kyle .... I never mix them
  14. townfanjon

    honeywell 2 port

    replaced a honeywell 2 - port actuator today, the valve/blackball bit moved very easily so I didn't change the valve body. strangely I only replaced the actuator off the original valve around 2 years ago. The custard had the system put in approx. 6 years ago, so in 6 years we are now on actuator...
  15. townfanjon

    potential floor problem

    gents, could anybody help me with this ... I need to move an unvented cylinder, its on a first floor with all pipes comeing to it from under the floor. Its in a very expencive appartment and is only about 7 Years old. I pulled up a carpet today and found a timber floor covered with a blue...
  16. townfanjon

    log burner / gas ppe

    Cant find the answer to this anywhere, can anybody help Pal of mine just bought a new house a few weeks ago. It has a logburner already fitted, but since moving in he has seen a old capped off gas pipe underneath it. (50 mm away). We are assuming its 'live'.I obviously want to remove it...
  17. townfanjon

    vaillant turbomax

    Gents, Pal rings me up this teatime, he's looked at a old Turbomax this afternoon that is going to be changed this summer anyway, his customer just wanted it to see the winter out, but its developed a fault HW working ok /no probs HTG works for around a 2/3 mins and knocks off, and just keeps...
  18. townfanjon

    bath panel

    dont think I have a hope in hell but its probably worth a punt !!! A good customer has bust her bath panel, the bath is a 1800 Sanctuary bath according to her its a Jacuzzi According to Jacuzzi it is not!!!! I think the place where she bought it has told her its a Jacuzzi. It is just a 1800...
  19. townfanjon

    Wanted Van

    Does anybody out there know where there are any good reliable vans for sale ?? My pal Roy Cropper is after one. His old tranny died on him the other night.
  20. townfanjon

    gas rating, again !!

    Gents, your thoughts please - commissioning a Viessmann 30 kw combi today (fit loads of them / love em ) Gas inlet working pressure on full load =19.5 mbar. Anylised ok, Spot on. Come to gas rating, again full load. Metric meter 86 secs over 2 mins = 27.78 gross = 25.03 nett. I can never...
Back