  1. M

    Split heat exchanger on ideal logic

    Yes Shaun I could see it dripping from the back of the hex too when I removed the little cover of the front of the fluing system. I guess there shouldn't be any water dripping from the hex even when hot? As the condensate all comes down the front through the inner flue duct and back to the trap...
  2. M

    Split heat exchanger on ideal logic

    I went to another ideal logic today. 8 years old with the same problem. Can I ask how long do you need to leave the boiler to cool do. I went and dryed the area out again under the hex and uped the pressure and it stated leaking down again. The hex was pretty warm though still for using the...
  3. M

    Split heat exchanger on ideal logic

    Yes going for a new one
  4. M

    Split heat exchanger on ideal logic

    I think the boilers nearly 10years old. What do ideal charge for a fixed price repair?
  5. M

    Split heat exchanger on ideal logic

    I did what you said townfanjon. And it worked a treat thank you. Definitely leaking he.
  6. M

    Split heat exchanger on ideal logic

    I was getting it pooling in the back of there.
  7. M

    Split heat exchanger on ideal logic

    I did get a drip or 2 down from the heat exchanger to the slump when turned off and all dryed out.
  8. M

    Split heat exchanger on ideal logic

    I went to a ideal logic that is losing pressure every week. So won't fire. Have checked all visible pipework and valves no sign of a leak. I removed sump cover on front of the boiler and there was water under the heat exchanger. I dryed this off left the heating off and the water came back. Has...
  9. M

    Anton pro 1 vs anton pro 2

    Lasted well then. Good to hear.
  10. M

    Anton pro 1 vs anton pro 2

    Is the anton pro 2 worth the extra money as apposed to the anton pro 1? I just think the 2 has the option of tightness testing etc. Also do most of you use/have the printer?
  11. M

    Changing fan on ideal independent

    I went around the seal with the analyser and got 20.9% oxygen. Though showed about 10 C0ppm
  12. M

    Piping up bath taps?

    I use flexis when swapping taps. Mainly due to the poor standard of fibre washers these days
  13. M

    Changing fan on ideal independent

    I wonderd about putting the probe around the fan seal. But would testing the air in take do the same thing. Show up if there was a problem with the seal. I'm probably over thinking things.
  14. M

    Changing fan on ideal independent

    I thought of an analyser but there would be fumes in there as the boiler case is off?
  15. M

    Changing fan on ideal independent

    Thanks I just wonderd if there was a way to. Test the seal wasn't leaking. I didn't think there was.
  16. M

    Changing fan on ideal independent

    If changing a fan on this type of boiler. Is there anyway to test the seal between the fan and the heat exchanger. There shouldnt be a problem as the seal sticks on then you just tighten the fan up to the heat exchanger via a bolt. I thought an analyser around the seal while the boilers...
  17. M

    Fitting a Mira 88 service kit

    Thanks could you send me the link to that site?
  18. M

    Fitting a Mira 88 service kit

    Thanks did you take the pistons out that mix it at the back?
  19. M

    Fitting a Mira 88 service kit

    Thanks roughly how long did it take you?
  20. M

    Fitting a Mira 88 service kit

    Did your replace all the orings? It's and exposed shower. Would you advise taking the shower off the wall or doing it in situe? Thanks