  1. melmos

    One for you commercial guys

    Public Ladies toilets having a problem with flow of water to washbasins. The taps are infrared with a solenoid, every morning when taps are tried there is only a trickle and its pulsing, after a few minutes they start to splutter and air is ejected and then a good flow of water. If left for half...
  2. melmos

    Bath/Shower Mixer Taps

    An acquaintance has had a new bathroom fitted, not by me. He asked me today about his bath/shower mixer tap, when he runs the bath taps the water is warm but when he pulls the lever for the shower the water is so boiling hot that he cant get under it. The tap has a TMV fitted set at 42deg I...
  3. melmos

    Flavel Emberglow gas fire

    Been approached by a customer who rents his house out, the front glass on the fire has been smashed. Is this a job for a gas safe engineer?
  4. melmos

    Leaking Ceramic Cartridge

    Called out to a mixer bath tap, been dripping for some time, owner had new cartridges that needed fitting. Put new cartridges on, but taps still leaking, so I took old ones home and put into an old tap and pressure tested to 3 bar, no leaks. Took back to house and replaced the new hot with an...
  5. melmos

    Air Admittance Valves

    Hi Hope that someone can advise on this problem. Went to a new build house, 7 months, owners having problem with downstairs toilet and main bathroom toilet which gurgles shower trap when flushed. There are 2 ensuite toilets which go to an external soil pipe open to the air, these are ok. The...
  6. melmos

    Worcester Bosch Greenstar i Junior

    Constantly having to fill system, have checked all pipework for leaks, none. Any ideas on fault before I call someone in, dont want someone replacing this and that if not necessary. Thanks in anticipation.
  7. melmos

    overflow fitting leaking

    Can anyone advise on best way to stop a washbasin leaking where the overflow adapter sits, the part marked. Should I use plumbers mait between the overflow fitting and the plastic nut as when plug is pulled water is leaking from nut
  8. melmos

    Cast Iron Waste Through Floor

    Can anyone advise on best way to cut down a cast iron waste that is protruding through the floor so that I can level it to the floor
  9. melmos

    Unvented under sink heater

    Hi, can anyone advise me if it is ok for a non competent person to install a 15ltr undersink unvented water heater supplying 3 sinks or do I need to get a competent person in to do the job.
  10. melmos

    Floor drain

    A friend wants to install a floor drain in his fish prep room, so he can wash down easier. He says hes been told that he can connect into a rainwater drain pipe running from roof through concrete floor, this is situated in far corner of unit. I dont think it is feasible, what are anyone elses...