Search results

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. A

    G/Worm Flexicom 24cx Pump

    Hi, The pump on the Flexicom boiler is working but grumbling a bit, I'm going to powerflush the system as it's really dirty. The pump on the boiler is Glow Worm badged, doesn't look like a Grunfoss, but when I've viewed it on a spares site, it shows a Grunfoss. I wondered if anyone knew if it...
  2. A

    Brittony water heater

    Go to the gas section & take a look at the closed topic & try emailing them.
  3. A

    Brittony water heater

    Experienced gas registered engineer req'd, or ask on the closed site
  4. A

    Be careful of Vokera Compact instructions !!

    A customer tells me, an engineer had visited the boiler & followed the MI instructions. No heating was the problem, but dhw worked. Heating calling, boiler fires up for brief seconds, shuts down, no pump running. after voltage checks as per MI. Changes PCB. Still doesn't work !! He walked away...
  5. A

    Termination of unvented cylinder T&P Relief

    Hi. I hold G3 certificate, but don't do much unvented. I've been asked to comment & advice on an exisiting PR pipe on an unvented cylinder in a cellar. The pipe is too small & is piped up to ground level !! The options are:- Enlarge pipe & terminate into exisiting waste pipes [1 1/2" ] which...
  6. A

    Worcester 35CDi domestic hot water... odd fault.....pcb?

    If it's heating up dhw, then burner goes off for a perioid, could be the plate heat exchanger, blocked on heating side. It gets too hot too quickly
  7. A

    How important is Gas rating ?!!!

    Hi Guys. Don't know if you're aware that there has been some Vaillant Eco Tec Pro 24kw boilers badged up as 28 kws. Just another reason to gas rate, as you and your customer may be not getting what you've paid for.
  8. A

    DIY Vokera repair?

    Have changed many dhw diapragms on the 20/80, not a diy'ers job. If the burner fires up & water gets hot then burner doesn't modulate but goes out for a while[ cold water] it ain't your diaphragm! You need to get an experienced GS repair engineer. It's a fan/flue related problem
Back