Search results

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. K

    Vaillant EcoFit Pure 835 Temperature Panel Control

    Hello all, Just moved into a house with a Vaillant EcoFit Pure 835 boiler that is 3-4 years old but the previous owner did not bother to register with Vaillant, so Vaillant says its not under warranty. I've noticed that despite setting the CH to 60 degrees on the boiler's control panel, the...
  2. K

    Ravenheat CSI85 (HE85T) boiler service SS14

    Hi, I am thinking of getting my 8 year old Ravenheat HE85T Combi boiler (also known as CSI85 I think) serviced. The boiler is running fine (touch wood) and has had quite a few parts replaced in its life. Can someone recommend a reputable service engineer in the Basildon/ Essex area: SS14...
  3. K

    Potterton Pprofile 50e Boiler help

    Hi, Another fresh problem for a monday morning My old trusty Potterton Profile 50e boiler has just been moved to a newly extended wall in the garden (approx 3.5 meters). The pump is still at the old location and the only thing that was moved was the two 22mm CH pipes and a new 22mm gas pipe...
  4. K

    Tee into a 3.5 inch Copper soil pipe

    Hi, I am installing an additional loo downstairs that needs to be connected to an existing 90mm/ 3.5 inch soil pipe (copper) running to the toilet upstairs. Found something like this but could not find not a Tee: WC Extension Connector for 3 1/2in MKEB - Multikwik - Guttering & Drainage...
  5. K

    Correct Replacement Mixer Tap Cartridge?

    Hi all, I've a mixer tap which is hard to close on the hot water side, so water is generally dripping. I've attached a pic of existing tap cartridge from mixer (left side) and a new 1/2 inch cermaic cartridge (right side). The right one goes into the tap but not all the way (due to a hole...
  6. K

    Potterton profile 50e boiler help

    Hi all, I've 2 questions: 1. My boiler is potterton profile 50e. At the moment the boiler is mounted on a brick wall and flue is directly out through the wall (same level as boiler). As I've an extension project coming up, can I modify the flue so it travels vertically upwards by 500 cm and...
  7. K

    Mixer tap connections for a steam shower cubicle

    Hi all Merry Christmas! I've received a pre-piped steam shower cubicle and the seller has asked me to just connect the mains power and cold + hot water (I've a balanced supply). For some reason I don't think his pipework at the back is correct (there is no manual to check). Could somone...
  8. K

    ON/OFF switch on Ravenheat HE85T (CSI85T) combi boiler

    Hello My 4 year old Ravenheat boiler HE85T (Exactly same as CSI85T) comes with an integral timer that can be used for various settings for all days/ weekdays/ weekends, which is working good. I generally use it to have 2 hours of heat in the morning + 3 hours in the evening every day...
  9. K

    Ravenheat HE85T combi boiler issues

    Hi, Ive a query regarding 4 year old Ravenheat HE85T combi boiler, this is very similar to CSI85T for those who know this boiler. The boiler has had new CH and DHW thermistors 2 or 3 times during its life so far along with ignition PCBs replaced 3 times. The boiler is currently giving issues...
  10. K

    Bleeding central heating rads issue

    Hi all I've just moved from a COMBI boiler system house to a house with conventional gravity fed DHW and pump based CH system. The EXPANSION TANK (at the top), the HEADER TANK (in the middle) and COPPER TANK (at the bottom) are in the first floor airing cupboard. The boiler is a POTTERTON...
  11. K

    Mixer tap on a gravity fed hot water system

    Hi all Just moved into a house and out of several things the wife complained about was that there were seperate taps for HOT and COLD in the bathroom sink. She wanted a MIXER instead and she gets what she wants. The basin HOT water tap is gravity fed but the mixer shower valve is pump fed...
Back
Top