Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. J

    Cast Iron stack & back to wall wc outlet

    Hi, Can anyone help/advise please ? this is my current connection - you can see the cast iron outlet is a fair distance below the wc outlet - but as you can imagine, it's a little prone to blockage :( The stack is marked 4" - but as you can see, the pan connector didn't want to fit very...
  2. J

    Sealed heating three tee rule

    Hi, So thinking about the three tee rule. I know it applies on the return (closet to boiler - bypass, hot water cylinder, heating return) so giving this some thought, does it apply to the flow (eg y plan or s plan) - are you supposed to put the bypass then hot then heating or is it only...
  3. J

    Recommend stop valve ?

    Hi, the main stopcock/valve for my house has decided it no longer wants to turn off. it is currently soldered to the 15mm rising main. Would any one be kind enough to suggest a quality replacement ? I've read in a few places that ball valves are now permitted for the main stop tap - any...
  4. J

    Worcester Bosch 15Ri Minimum Flow Rate & Auto bypass

    Hi, I have the worcester bosch 15Ri boiler already installed. I have a salus bpv100 auto bypass, multihead g pump on speed 2. Does anyone know the minimum flow rate the boiler requires (I can't find it in its manual, unless I missed it) so I can adjust the bypass valve appropriately. Thanks...
  5. J

    Old style radiator heat output

    I have an "old style" radiator in my hall - it has no "fins" on the back. I reckon its about 20 or 30 years old. Its double panel and measures 127cm by 60cm approx - does anyone know roughly what its heat output might be please ? thanks
  6. J

    External Condensate - Options

    Hi, As you can see from the image, my condensate is part 22mm and part 32mm. I would like your opinion on various options, to (1) make it less noticeable if possible and (2) prevent it freezing. 1. Change entire pipe to 32mm (including through the wall), with a 135 degree bend rather than...
Back
Top