Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. A

    Promax pump

    Whats the cheapest way to replace these, don't want to fit a spare one I've taken out a boiler as it's for an old dear, wouldn't want it to fail in the near future. Genuine part seems pretty dear, was thinking of just fitting a UPS2 head...
  2. A

    Zanussi boilers

    Anyone know much about this? GSR mag has an ad about offering your customers a finance deal
  3. A

    Vokera Mynute gas valve

    Gas valve not going to low burner with a wire removed from the modulating coil, are the coils known for going? If so can you replace just the coil, or is it new GV time?
  4. A

    Worcester Greenstar 35HE Plus

    Have a customer who's been having issues with the boiler going to A1 lockout, usually noticing the problem when using HW, mainly in the shower, running hot and cold. They've had WB out who have changed the gas valve and the plate HEX, also 2 thermistors. However, the major problem seems to be...
  5. A

    Worcester heat exchangers

    Heard about this once or twice but have never seen it...... until today..... twice! Two customers today with CDi Classics losing pressure quickly, investigated and soon found both had a split HEX, losing water down the condensate. One 7 years old and one 10. You guys find this a lot? I have...
  6. A

    New Logic +

    Fitted a good few of these now, great wee boiler, except for the new wiring connections!! Anyway, fitted one a month ago and the customer is complaining about the boiler still running after a demand. Been back to check it out, and the over run time is about 4 minutes, same as a few others i've...
  7. A

    40CDi combi problems

    Called to a leaking 40CDi, leak was coming from the flow turbine housing. The cartridge with the flow restrictor in it had perished a bit causing the leak. So ordered a new one and planned to go back tomorrow.... But the plot thickens.... I left the hot water switched off, but before i left...
  8. A

    Alpha 280e

    Not firing on this one. Fan runs and aps light goes out, so all good there. No sparking or power to gv, got 240v going to ignition board. Electrodes were out of shape but moving them made no difference. MI's say replace ignition board, always a tad worried on board replacements just in case...
  9. A

    Ideal Classic FGA point

    Serviced my 1st Ideal Classic today, noticed there wasn't any cover on the FGA sample point, called Ideal and they said there should be a rubber cap on it, but they didn't seem to stress it was a danger. The property is getting renovated so is empty, I've ordered a kit with the rubber cap in it...
  10. A

    Baxi 105e

    Got a fresh batch of gas certs/services to do for a new landlord, 1st one I go to has a Baxi 105e, tenants shows me that the gas hob goes out when the boiler fires up! Turned out the gas valve handle was off and the valve was just cracked open, this boiler was seemingly serviced by BG in...
  11. A

    Worcester Junior condensate seals

    Servicing a 4 year old Junior today, the rubber seal on top of the trap didn't want to seal again. Had this before on a Ri, greased it up and it was fine. Had this one out 3 times adding grease and turned the rubber round, just kept letting a little condensate out. Ended up using a little clear...
  12. A

    Potterton Prima F

    Going to look at one of these on Wednesday, cust the boiler won't come on unless they put the power off at the spur for a while and then power it back up again. Sounding like a board issue to me... Common fault with these?
  13. A

    Ideal Logic gauges

    Serviced 3 Logic+'s today, two of which when the heating is running or the pump over run is on after demand, the pressure gauge needle is rattling about so much it is actually noticeable from within a 3m range from the boiler. Luckily ones in a cupboard so that drowns out the rattle, but the...
  14. A

    EcoTec diverter valves

    These easy enough to strip and clean out? Got a cust with a Pro 28 dumping heat down the flow. Dirt inside will prob be my 1st check
  15. A

    Promax HW flow

    Just fitted flow restrictors to my whb tap so the kids dont make a mess when washing their hands, fitted the little cartridge type that inserts into the pipe/fitting. Fitted pink ones, also have a few red here. Now the HW wont start on the boiler, looks like it should though. Do the hall effect...
  16. A

    Ideal Logic + F9

    Anyone know what causes the Logic range to go to F9 fault, MI's just say PCB fault-replace PCB. Serviced a 24+ Heat today, 1 year old. Carried out the service, fired it up and ran through FGA checks etc. Tidied up and was talking to the customer and noticed the F9 showing. Wouldn't reset...
  17. A

    Vaillant Pro28 R1

    Got a neighbour with one of these who's having a few issues. 7-8 years old, never been serviced. Prv was passing on it and it was rattling I was told. Sure enough prv was passing and the pump sounded like a bearing was shot. Looking at it, needing a prv, pump and a burner gasket for servicing I...
  18. A

    Bad flue repair

    We're doing a bit of refurb work in a rented commercial property, the gas work is being carried out by the landlord's so called engineer. My partner was round yesterday afternoon, on arrival he spotted a new Worcester Greenstar flue sticking through the wall with a terminal guard fitted...
  19. A

    Boiler lead companies

    Anyone ever used companies that sell you boiler leads, tempted to give them a try, but unsure if it will actually be worth it. Its just installs we are looking to do
  20. A

    Ideal Isar hot water issue

    My Dads been having trouble with his Isar M30100 for a few months now. First time I've worked on one of these, as I know there reputation! If its an easy fix I will sort it, if not its new boiler time. As i dont have a great deal of experience with these, I'm looking for some advice. CH works...