Search results

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. B

    back boiler servicing

    got to service a baxi 50/4 with I think a tempest fire front I do hardly any back boilers as there don't seem to be many around here does anyone have a sequence so its done methodically I get there but I tend to take a long time (as I seem to myself to do things backwards) also does anyone have...
  2. B

    glow worm energy

    how do I access installer level very little in installer manual unless I am being dense want to put it on min burn
  3. B

    back boiler ventilation

    vent is in floor don't think its ducted Is it AR to be honest its going to be difficult to explain to this old boy why he has had it serviced year after year and no one has mentioned the vent being an issue so if its not AR I will let it pass
  4. B

    link in vaillant

    I fitted a vaillant 835 and 350f wireless thermostat should I have taken the link out or does it matter
  5. B

    thanks to worcester bosch

    just sat my re assessment at Worcester bosch £400 instead of £1400 locally and when I found out I could use my Worcester points I asked for a refund and they gave it to me cant say fairer than that before you all rush off to do your re-sits with them we were six"lads" with 200 + years in the...
  6. B

    overflowing cistern

    fitted a drayton 3 port and the cust asked could I sort this it looked like a botton entry float operated valve grey with a red float I should have taken a photo but didn't it has a Fordham style washer if anyone no the model does this have those nasty nylon locating pins if it does it almost...
  7. B

    solanoid on gas pipe

    been asked to help a dementia suffer as there carer wants the gas pipe turned off overnight my only thought was an electrically operated solenoid has anybody done this or has anyone any other thoughts
  8. B

    thoughts on a leak

    I re piped the gas in an old cottage im drilling the route of new pipe through bedroom to dining room and hit a plastic water main that's run in the coving in the room below(dining room) i don't feel i could have anticipated it being there and don't want to claim on my insurance anybody have...
  9. B

    break tank booster set/accumulator

    had a few job lately were it needed a bit more oomph has anyone fitted booster sets domestically and do they do the job or are they more trouble than there worth and what are the better ones and their cost
  10. B

    boiler in bathroom

    what are the rules regarding an existing boiler in zone 1 and replacing it
  11. B

    servicing worcester

    don't want to buy the big bog brush and the coat hanger for 30+ quid can you do it okey without them
  12. B

    gas safe audit

    I have a gas safe business audit it says show all paperwork and I can guess at most of what they want but it would be handy to get a full check list from one and all for starters I would think all paperwork I issue lgsc ar and id ed 7 GIUSR nd now ive run ot iof ide
  13. B

    scrapping elson tank

    if anyone does sheet lead work and wants some sheet copper to tin I am scrapping an elson tank and they can have the sheet copper for scrap price
  14. B

    vaillant on a one pipe

    can it be done is it okey its a domestic property had a pott prima b/f a cylinder on gravity and a pump on 15mm doing what appears to be a one pipe its bottom entry opposite end for the rads and my mate is fitting an 831 I just want to know if it will work okey
  15. B

    copper sulphate in pipe

    commission a boiler yeaterday and the pressure at gas valve was 7mb, test point I fit next to boiler 18.6mb so called manu fro new gas valve but the problem was copper sulphate (black dust) so I accept they sholdnt fit a new valve but they have said to re pipe the whole of the gas supply has...
  16. B

    ideal icos he18

    pcb dead so fit new pcb still dead check gas valve 200v 22mbar inlet -3mbar outlet check venture clean burner straighten spark electrodes fit new sensing electrode check continuity of detection lead clean condensate trap it will work very occasionally but no where near enough to pack tools away...
  17. B

    back boiler service

    doing a bbu service this week have mi,s have everything pretty much under control but as I am not a service engineer I do want to cover absolutely evey angle so I have a question for those who do these quite often does anyone put a smoke pellet in the flue liner when they do the boiler I think...
  18. B

    15mm pipe bender

    does anyone know where to buy a 15mm pipe bender I have got a 22/15 but some times I,m too lazy too carry it around and I don't want a spring my knees are sore enough
  19. B

    service gas fire

    been asked to service a gas fire but I have a feeling its a fire in front of a bbu that's no longer being used I should have had a better look but I was in a rush and said I would get back to it its a baxi Bermuda 552
  20. B

    fitting nest

    being asked to fit nest thermostat to 38kw vaillant has anyone fitted these nest on here I don't really like going in without any idea about the product so a heads up would be good
Back