Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. L

    Heatline Capriz Plus 24a

    Hi guys quick one would you replace the insulation panels in the combustion chamber if they were submerged in condensate, i ask this as i just been to a breakdown and the condensate was blocked backing into the chamber and then leaking out of the spark electrode which eventually causes the spark...
  2. L

    Worcester 28 cdi rsf combi

    Hi guys on the way home tonight got a call about banging noises from the boiler decided to pop in as it was en route and found that the boiler fires then what sounded like air rushing/lumping through it about ten seconds after when the hot water tap was opened. The boiler then cuts out and...
  3. L

    Ideal Logic in disguise

    Hi Guys Just after a few pointers not really done a lot of faultfinding on boilers but been too a friends who has a ProCombi Exclusive installed in his house. Which i believe is just an Ideal Logic, he realized that the pressure was dropping around 1 BAR every week. He has kept a keen eye out...
  4. L

    British gas 532i boiler

    Have a problem with a boiler it is a bg 532i combi which I believe is a slightly modded Worcester bosch greenstar. problem is with the heating side of the boiler it does not work. Unless you use the ch boost (chimney sweep) button. I have linking out the room stat and still no joy. Question is...
  5. L

    British gas boiler 532i

    Have a problem with a boiler it is a bg 532i combi which I believe is a slightly modded Worcester bosch greenstar. problem is with the heating side of the boiler it does not work. Unless you use the ch boost (chimney sweep) button. I have linking out the room stat and still no joy. Question is...
  6. L

    Alpha cd28x

    Hello i have an alpha cd28x combination boiler and the hot water seams to initially be fine then runs cold after a few moments. The boiler then has all four lights flashing on the panel and I need to reset the boiler to be able to get and hot water. Any help please as to what could be the...