Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. M

    Auto bypass valve problems.

    I've read the baxi duotec and the 600 boilers already have a Integral bypass but I've seen overheat problems with the 600 boiler when the lad has turned but one radiator off with 8mm pipework and I've also seen a pump fail after 2 years on a baxi duotec.. I assume a bypass should solve these...
  2. M

    baxi duotec

    Hi, another baxi question, fitted an A rated grundfos pump, boiler was working fine but now and again after fitting this pump i get E168, tried on setting 1 and 2, still randomly get this error.. once i reset its back to normal... Dont they like the lower Wattage ? The other change is balancing...
  3. M

    Baxi duotec 24HE,A

    Hi. I'm having an issue with high CO. Into the thousands ppm. The gas supply is 22mm 20mb. New gas valve. Adjusting it only makes the CO worse. The flue is good and intact. Any ideas guys ?
  4. M

    20 rads

    Power flushed a one today, 20 rads, some are great, like the back of the house where its been re-piped, others on the old system not so great, warm, you can keep your hand on them, theirs 2 on the old system like that and the last one, the furthest one away is new, piped up in 8mm and again...
  5. M

    Pressure Reducing Valve.

    Hi, i'm having trouble with a prv, i fitting one to the mains supply and the flow rate is now pretty poor.. My thought was that a prv shouldnt really reduce the flow rate, but finding any info on flow rates regarding prv's seems pretty hard to find.. cheers for any help.
  6. M

    worcester junior 24i

    is it possible to adjust the burner pressure on this boiler ? this boilers burner pressure is too high, i couldnt see any way to adjust it, so i'll probably end up buying a new valve tomorrow. also at the same property, the working pressure went right down to 15mb, so i called out the gas...
  7. M

    location of flue outlet

    if a fanned flue exits above a garage flat roof at 300mm but also has the property roof up from the garage roof which every winter, it gets a snow avalanche, leaving about 3 feet deep.. still legal ? aps turns boiler off anyway. thoughts?