Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. S

    Worcester cdi EA fault

    Hi guys Does the worcester cdi have an internal bypass? Long story short ive done some ufh on a worcester cdi not a big system 7 rads and ive added a 10m2 conservatory pack. Both zone valves ( for ufh and radiators ) have been left locked open untill spark goes back. Just over a week later...
  2. S

    worcester cdi

    Hi guys worcester cdi is giving out lukewarm water, measured at 33 degrees at all outlets. Heating is working fine. Taps are working fine. Diverter valve is operating. The ho****er outlet pipe at boiler is hot to touch. I dont think plate is blocked as temp doesnt rise high and the burner...
  3. S

    Flue question

    Hi guys been to a boiler today the house is a terraced with alleyways between the properties about 1000mm wide with a ceiling and open at both ends. There are arches at the ends which are 400mm below the ceiling ( sure youve all seem them ). The boiler flue goes into this alley. It then has a...
  4. S

    Ideal isar

    Hi guys thanks in advance had an intermittent fault on Isar traced it to board,put new board in and everything dead. Theres power to boiler, power going to board, fuse is good ( has continuity ) no power going to the boiler power switch? Has it blown a new board? Or am I missing something...
  5. S

    fire and stove reatailer

    Anyone own a fire a stove shop? Was thinking about setting up and could do with some advise. Cheers
  6. S

    room stat

    Hi guys, when wiring a stat I.e honeywell t6360 where do you take the neutral from for anticipator? It shows from the spur on wiring diagram butt don't think I've ever seen it, most I've seen Havnt got the anticipator wired, can you connect to the main terminal neutral in boiler? Cheers
  7. S

    ideal classic nf

    What do you do about FGA on a boiler like the ldeal classic nf where there is no test point and you cant get to the terminal? MI do not state FGA is required so is there no need?
  8. S

    commercial gas

    does anyone know roughly how much it will cost to do commercial gas??
  9. S

    Honeywell V4600C1029U 240V Gas Valve for sale

    i have 2 of the above gas valves, the boxes are abit tatty cuz they been in the van but valves are perfect and still in fil wrapping, let me no if your interested, cheers
  10. S

    Honeywell V4600C1029U 240V Gas Valve

    i have 2 Honeywell V4600C1029U gas valves new, the boxes they are in are abit tatty as been in the van but valves are in perfect condition still with film wrapping around them
  11. S

    BBU fire front

    can a redundant bbu be left in or do i need to remove and install flue box? cheers
  12. S

    boiler earth bonding

    when bonding at the boiler do you just cross bond the pipes or do you need to run earth cable back to the earth block at consumer unit? cheers
  13. S

    no fused spur on boiler

    There is no fused spur next to combi boiler, i assume the boiler, clock and stat are wired to a wiring centre then straight to consumer unit, is this correct?? thanks
  14. S

    combi install

    alrite guys, finish my gas course soon and got a job lined up for when i finish, customer wants new boiler and wants it installed in airing cupboard, which is in the middle of house. question :- is it ok to run the condensate and blow off under the floor boards as long as they are falling??
  15. S

    confused with worcester

    hey guys, WGS28iJ - flow rate 11.4 WGS25Si - flow rate 10.2 WGS30Si - flow rate 12.3 im abit confused with these 3 boilers as everywhere i look they are listed as 24kw boilers??? is this right?? thanks
  16. S

    boiler size??

    hey guys, i have calculated rad sizes, how many KW do u add on for hot water when sizing the boiler?? thanks
  17. S

    Gas safe

    hey guys, if your gas safe registered as an employee, not in your own right, does this mean your breaking the law if u do a foreigner? ( im talking about gas law not tax law )
  18. S

    Radiator sizing

    does anyone know a quick method of sizing rads without using a mears calc or a computer program. an old plumber once told me cube the room up in foot then times 5 then this is BTU.....something like that anyway
  19. S

    pipe wrapping

    hey guys, just wondering why the heating pipes in my house are wrapped in what looks like hessian?????
  20. S

    finding work

    hey guys just looking for some advice, im a new company operating as a sole trader im getting work in, mainly maintenace jobs but i would like to get in with a builder doing new builds, first and second fix, as im not that keen on driving from house to house unblocking toilets and changing rad...