  1. N

    electric water heaters

    Hi chaps, Never really had anything to do with them but have a quote to do for a large school, just need an electric water heater to deliver to four sinks in the art department. Just wondering if any one has any good or bad experiences with any particular brands. Notice the Williams catalogue...
  2. N

    DIY Project To Zone My House

    I thought it was the order or way that your cylinder.heating and bypass returns were piped up to avoid reverse circulation. But can't actually remember what the rule is since I don't install whole systems really, but I know the cylinder is the last connection after bypass and central heating...
  3. N

    which combi

    Hello all, wondering what combi's people are using at the moment. Ive got a house to flat conversion for a landlord customer. The GSR did the boiler quotes and priced for worcester 25si's. Had a little look around and realised I can save a fair which by going either ideal or glow worm. When I...
  4. N

    DIY Project To Zone My House

    Well for a diy tiling job I'd say that's pretty damn good. It's not professional because you didn't measure out correctly first and start from the centre of the walls. Which is why you have smallish cuts at the top and at the end of the walls, and they are not symmetrical at each end . TBH I...
  5. N

    Metal waste's

    Hello all, Been doing some contracting work just ripping out bathrooms and putting in new for the council. Most of them still have the old copper waste pipes which go into the stack using a nut and olive. Now usually I can just connect my plastic pipe on to the metal pipe with a compression...
  6. N

    slightly naughty gas engineer

    afternoon all, a question for gsr's. I'm doing my gas hours at the moment and got a call the other day from a gsr I know asking me if I wanted to help the with a boiler install. I went along and helped. We replaced an old ariston with a new glowworm (both 24). When I commissioned it there was a...
  7. N

    unvented leaks

    Hi everyone, Before everyone asks the usual questions, I do have my unvented ticket, but besides a few installs I haven't used it much so I'm a bit rusty, normally I just go out with the guy I'm doing gas hours with but he's away and this customer is just around the corner and I want to make...
  8. N

    qualified plumber 2 years exp, will work for free - in exchange for gas hours/exp

    posted this in the general forum, then thought it might be better posted here. Willing to work for cheap on non gas work as well to build up more experience. Hi everyone, ok so my situation is I need to build up my gas portfolio. I have my nvq2, tech cert 2 and 3 (including gas foundation) and...