Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. B

    Ariston Euro Combi 30

    Does any of you have any experience working on the Ariston Euro Combi 30. I have a leaking diverter valve cartridge but there is no room above to remove it. The sealed chamber floor is is only about 30mm from the top of the actuator head which also cant be removed. Do you have to remove the...
  2. B

    10mm plastic to feed kitchen sink

    I concentrate on boiler and heating repair but I'm doing a first fix on a kitchen to keep a landlord sweet. The kitchen is a total rip-out and is back to bare bricks. I'm fitting a new combi boiler. Just want someone to confirm if it's ok to run the hot & cold in 10mm plastic to the kitchen...
  3. B

    Frozen condensate pipe

    Been out to loads of these last week but unsure how much to invoice agent for. What are you guys charging for this?
  4. B

    Servicing Drayton motorised valve circlips

    Does anyone know where I can buy the correct circlip for the spindle on a Drayton motoised valve?
  5. B

    Can anyone identify this basin tap

    Can anyone identify this basin tap please? It has a single letter "G" at the back. I really need to know how to get the thing dismantled so I can replace the cartridge. Any ideas?
  6. B

    Multi meter room

    Does anyone know where I can purchase a large diagram/label for a multi-meter installation room? Its the one where you have to write in the number of meters installed for a block of flats.
  7. B

    Renew water regs

    How often do have to sit a re-assessment?
  8. B

    Main combi 30 Eco DHW gets hot until... the CH is calling

    Can anyone confirm my thoughts on a solution to this boiler fault? Went to the above boiler yesterday and the hot water works perfectly until there's a demand for CH. The hot water keeps going cold when there's a demand for heating. The hall sensor was lighting on HW demand. I took off the motor...
  9. B

    Baxi 105HE 60 light flashing

    Called out to this boiler 475-75-18 today with 60 light flashing on demand for CH or HW. Fan not runnng. Pump proving fault i understand. Pump runs, no air in boiler. The CH differential valve pin is not lifting on demand. I can force the boiler to light by holding up the microswitch. I changed...
  10. B

    Instant 105e Upstairs rads get hot when preheat turned on

    Also system pressure loss (PRV leaking). Been twice before to recharge PV. Are the two issues linked or do we have two separate problems? I suspect div valve passing when DHW on preheat. Can anyone tell me which seal will need replacing?
  11. B

    Ariston Clas HE

    Customer rang me to say no CH or HW or display on boiler. I haven't been yet but if she isolates the boiler, turn the power on again and there' a few flashing lights before no display again. Any ideas anyone?
  12. B

    BAxi 105he APS wires

    Went to a job today on a 105He and found someone had previously replaced the APS for one of the white round plastic type. I suspect they may have replaced the wires incorrectly on the terminals as its not that clear. The MI's aren't specific about this so was wondering if anyone can tell me...
  13. B

    No hot water Ferolli Optimax he31c

    Went to this boiler tonight with reports of no hot water; heating ok. There were no fault codes. Sure enough heating working but no hot water when there's a demand. The manual for this piece of crap is useless as there is no info for changing parts or fault finding guide. Couldn't contact...
  14. B

    Balanced flue gas fire

    Is it normal to check the POC on a fire with a balanced flue and decorative flame effect, with the flame effect tap switched on or off?
  15. B

    Gas oven supply pipe

    Most properties have a built-in hob with a built-in electric oven below it, or a free standing cooker connected with a flexible rubber hose. It is not common to come across a built-in gas hob with a built-in gas oven below is it? This had me thinking, is it acceptable for a built in gas oven to...
  16. B

    3 or 4 sided gas fire?

    Apart from the obvious, does anyone know the difference between a 3 and a 4 sided fire as per the following link? The manufacturer states that the 3 sided will fit into a standard opening but I'd like to know more. Like where is the missing side? Crystal Fires - Royale
  17. B

    Glowworm Micron 40ff fault finding

    Why, when following the fault finding guide in the M/I's of a Micron 40FF does it suggest checking 6 LED's when the board appears to only have 2 LED's? I think the lights illuminate in conjunction with the ignition sequence.
  18. B

    Glowworm Micron 40ff led's

    Why, when following the fault finding guide in the M/I's of a Micron 40FF does it suggest checking 6 LED's when the board appears to only have 2 LED's? I think the lights illuminate in conjunction with the ignition sequence.
  19. B

    Cannon fire instructions

    Does anyone know where I can find the installation & service instructions for a Cannon 26730C ilfe gas fire please? I am usually able to find docs for the most obscure appliances but I've searched till my head is sore without success
  20. B

    Fanned gas fire goes out after 10 minutes

    I realise there's another recent post on here about a gas fire going out after a while, but I had the same problem when servicing a fanned flue fire the other day. I was told about the problem before I touched the fire. The fire lights and stays on for about 10 minutes then reduces to low flame...