Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. Deleted member 32524

    Hi, old DIY idiot joining forum

    Hi TonyT. Hello and welcome. Sounds like you may have a few tricks up your sleeve too.
  2. Deleted member 32524

    Vokera Mynute 20 VHE.

    Hello, Thanks for looking. Been to see above and it is needs heat exchanger cleaned out. been told that I need to take a 0.4mm tool from vokera or a feeler tool to clean. Where is this tiny gap that needs cleaned? Any tips on the best way to clean it, thanks. Thank you, Duncan.
  3. Deleted member 32524

    Vaillant EcoTec 831 intermittant noise

    Hello, Thanks for looking. Got called to above to a report of it making a noise, intermittently, no fault codes. Checked CO2 levels and it was at 8.5%, put it to 9.0% as per MI. Thought that would cure it, but no. Had a call today to say its back. I have not heard a peep? Runs smoothly when I...
  4. Deleted member 32524

    commercial catering advice

    Hi, Just wondering if anyone is in commercial catering? Looking for some advice. Thanks, Duncan
  5. Deleted member 32524

    Vokera excell 80 sp combustion door seals

    Hi. Picked up new combustion door seals for this earlier and chucked them in van, just checked them and there is only 3 strips in bag about 1m long. Anyone know if I will get away with 3? Looks to me like I would need min 4 to do it all. (Did ask for 5 but spoke of the three doors, think he has...
  6. Deleted member 32524

    Vokera option no gas through to burner

    Hello. Been at above and have continuity @ overheat stat, sparks then goes to lock out. No gas @ p2. Ta, Duncan
  7. Deleted member 32524

    ferroli modena 102 standard efficincy

    Hello all, Need some help with above boiler. Keeps cutting out on hot water and CH. Works fine with cover off. Thermistors test ok. Replaced venturi, no joy. Got to be an air problem but what? No blockage in flue. Thanks for the help. Duncan
  8. Deleted member 32524

    compact A vokera

    Hi folks, Thanks for looking. I have a compact A that is loosing pressure. Expansion vessel holding charge, PRV not passing. No obvious signs of any leaks. I closed off ch pipes and still slowly loosing pressure, so must be on boiler. Any thoughts on what might be leaking? Also no pass...
  9. Deleted member 32524

    filling old flue hole

    Hi all. Thanks for looking. I have 2 questions 1 how to fill old flue hole that does not conform to regs. Problem is its 3 floors up. Can't be reached from window. How to fill from inside!!?? If even poss. 2 gas line has to go past electric maim isolation switch before consumer unit. Only...
  10. Deleted member 32524

    Cleaning out copper tube of dust.

    Hello, Thanks for looking. Been on a job an there are many other trades coming in and out. The place has turned in to a dust zone with rubble, deading etc all been disturbed. My 28mm and 22mm copper for the gas line has ended up being moved and now it has a film of dust in the tube. Would like...
  11. Deleted member 32524

    ariston eurocombi

    Hello, Went to service a ariston eurocombi last night and the front panel seal that seals the chamber is totally ruined. Just phones technical to get a part code for a new seal and have been told to use heat resistant silicone!? This does not sound right to me but, it was their technical...
  12. Deleted member 32524

    open vent boiler mate 2000

    Hello, Boiler not getting a sl from this boiler mate and not firing. Never seen one before boiler mate 2000 that is. It looks like the boiler gets a switched live from there but there is no voltage on the sl at the boiler mate. Every other connection has power when it should. All the lights...
  13. Deleted member 32524

    fan pressure at venturi

    Hello, Went to Vokera 25he. Pump starts, fan runs, no ignition. Cleaned Ventures still no ignition. Put FGA on venturi. Reading looks low. Anyone got an idea of what it should be? Thinking lazy fan. Thank you. Duncan. Ment to add tubes clear and no splits.
  14. Deleted member 32524

    Vision filling loop

    Hello, Installing a vokera vision 25c. What is the script with the filling loop? In the kit I had no washers, if there are any. Thinking tape and jointing compound. Or are there fibre washers? Thanks for looking.
  15. Deleted member 32524

    Vokera Vision 25C

    Hello, Thanks for looking. Installing a Vokera Vision 25C. Finished putting in service cocks and went to put on the filling loop and there was no washers. Put it on thinking it must have an internal seal, but it started dripping when I started filling up to commission it. After 5 when I...
  16. Deleted member 32524

    What would be a recommended slim line boiler?

    Hello, Thanks for looking. Got the opportunity of a boiler installation. Problem is space. Tight. Location is next to a window so, cant move it over to left. To the right there is space, but cupboards in the way for access to remove front cover and hamper getting in to parts etc, not by much...
  17. Deleted member 32524

    Vokera Linea hot water problem

    Hello, Above boiler when shower runs cuts out at 38 deg, CH shows 90 deg when I close the filler loop. Thought partially blocked DHW. Flushed through pump head twice with chemicals, still same prob. Thought maybe primary thermistor fault? Cant get to it to test it, cant get a reading on board...
  18. Deleted member 32524

    Powerflush through pump head.

    Hello, Doing a powerflush and I have bought the pump head adaptor for my Kamco machine. Question is. Has anyone has any problems using this method i.e pumphead not sealing properly once you put it back on, etc?
  19. Deleted member 32524

    potential savings from a power flush

    Hello all, Thanks for looking. Just want to see if anyone has some facts about what savings you would see or not. Also what is the most important factor for an efficient flush, like flow or horse power/watts... Thanks, Duncan.
  20. Deleted member 32524

    Fixed price repairs a good idea or not

    Thinking of doing fixed price repairs. Does anyone else do this or work for a company that does. What is the charge and how often do you get stung? Thank you for the help. Duncan