  1. P

    Shower outlet question!!

    Been to a job today and somebody had decided to use a street elbow and a soldered male iron for a wall outlet instead of using a standard back to wall elbow! There is no way to change this without damaging tiles/plasterboard behind and the property is rented so landlord doesn't really want...
  2. P

    2 x defs in the same room

    hello fellow engineers! wonder if you can help me out ? two decorative effect fires in the same room where should the vent be located?
  3. P

    gloworm 45/60 floorstanding boiler manual?

    Hey does anyone know where i can find a manual for a gloworm 45/60 floorstanding boiler?
  4. P

    Electric shower not getting enough pressure through it to heat the water

    Just spoke to a customer and they are saying they have a problem with there electric shower where they are not getting enough pressure through it to heat the water so its cold all the time , she said its always been a bit funny and they sometimes have to run a tap then turn it off quick to...
  5. P

    baxi solo 2 50 pf problem

    i have a customer with a baxi solo 50 pf and the boiler cuts out randomly it was working all ok when i went there but there was a red light on the 'over heat' and red light on the 'boiler on' , has anyone heard of this problem ? any help would be much appreciated !
  6. P

    Gas fire advice turbo toaster mk3

    Im a gas safe registered engineer i went to look at a broken royal cozy fire , the turbo toaster mk3 today the piezo igniter is sparking but there doesnt seem to be any gas coming out when the gas control is set to ignite and pressed in , ive cleaned out the oxy pilot assembly but still no joy ...
  7. P

    gas meter flexible connections ?

    im doing a boiler installation at the moment and i noticed the gas meter inlet and oulet are lead pipes coming off the meter are these classed as flexible connections as obviously flexible connections arent allowed??
  8. P

    glow worm flexicom

    what are peoples thoughts on these ? ive been asked to change a boiler but he wants a boiler with a back entry flue coming out and the only one i can seem to find that does this is the glow worm flexicom but obviously i want to fit a reliable boiler for them so whats everyones thoughts and...
  9. P

    Gas hob isolation valve behind a gas cooker

    what are the regulations ? obviously the hob has to have a rigid connection and a means of isolation but is ok for the gas cock to be hidden behind the electric oven or does it have to be accesible ? say in a cupboard next door etc . THE TITLE WAS MEANT TO SAY ELECTRIC COOKER SORRY!
  10. P

    Gas inspection

    Hello everyone im gas safe registered now got my card through and everything passed in november :) , i got a letter saying a gas inspector will be coming out to see me and if i dont have any jobs to show him i will have to do a competency based inspection at my address , has anyone had this and...
  11. P

    gas rating heat input

    doing my acs at the moment just a general question when you put a boiler on calibration mode for example the baxi duotec combi and you have worked out your gas rate and heat input calculations , what input do you refer to in the manual to compare it to ? i know its gross but is it the CH or DHW ?
  12. P

    room sealed flue

    im currently doing my gas courses at the moment but im struggling to find this in my viper book/notes i know for open flued boilers it has to be 600mm before a bend but is this the same for room sealed ? or can it be elbowed straight away all help appreciated piperdave
  13. P

    providing evidence for gas course

    basically im looking to do my gas courses and will be going in a a category 2 as i have a city and guilds qualification and work with a gas safe engineer , i was just wondering what sort of evidence do i need to give and is there a criteria for it if you know what i mean ?
  14. P

    acs gas course

    basically im looking into doing the acs course to get more chance of getting a decent job and decent pay as im getting taking for a mug at the moment, i have 4 and a half years experience in plumbing and heating and am getting really poor pay , ive tried ringing loads of companys but knowone is...