  1. B

    WANTED: Grasslin Famoso 601rf timer thermostat

    Thanks for looking it up. I was trying to get a freebie on here lol. But, I should have one soon.
  2. B

    Is there a stand alone multiroom controller for wireless TRVs?

    Thanks. The honeywell one seems to be the only one that works stand alone and it looks like a good product and I have seen it from only £150 for the controller. However, the only problem is that the TRV's seem to have a manual override which defeats the point. I want to be able to keep...
  3. B

    Is there a stand alone multiroom controller for wireless TRVs?

    Hi, can anyone recommend a controller for wireless TRVs that can set on off time for individual TRV using a phsical control panel with it's own interface/screen that does not need a smartphone app to work and can be used stand alone?
  4. B

    WANTED: Grasslin Famoso 601rf timer thermostat

    Hello, the clock broke on my wireless mechanical timer thermostat for my baxi boiler. The item is 20 years old now so someone might have a spare one from removing an old boiler. The Grasslin famoso 601rf was supplied for several brands but its the same other than badge, e.g. baxi, ideal, alpha...
  5. 1728749589024.png

    1728749589024.png

  6. B

    leak on new plate exch

    The boiler is a baxi combi The pipe underneath on the left side of the plate exhanger where the DHW hot water comes out has green corrosion and signs water has dripped on the floor below it. The plate exchanger was replaced a few months back so is nearly new. The pipe was not green before the...
  7. B

    Is powerflush really any better than chemical plus mains flush? (before boiler repair)

    Hello, BEFORE I cleaned the system last year with a mains flush. There was a little inky stuff and a bit of sludge at the very end when I emptied out the rad I took off the wall, but no rads have ever had cold patches. Most pipes are hep20 but I had small section replaced by copper 2 years ago...
  8. B

    How to drain down to remove towel rail AND valves?

    Towel rail needs to be removed so that new flooring can fit over pipes. Therefore the whole thing needs to come off valves and all so that the pipe ends coming up from the floor are exposed. The bottom compression nut and olive can stay on each pipe as there will be big enough holes in the...
  9. B

    Gas fire closure plate

    Hello, I have a gas fire which has been unused for some time. It has a rectangular vent protruding from the rear. There used to be a closure plate with a rectangualr slot but this is now lost. The closure plate for this fire is no longer available as a spare part. Q1. Do new gas fires...
  10. B

    Cylinder pipe sizing for new hot water system

    Current system: Combi boiler with direct cold water all on 15mm pipes. 28mm outside diameter lead pipe from supply converted to 15mm copper to kitchen tap and then onwards to bathroom. Proposed new system: No more instant hot water from combi. Replace with hot water cylinder with 2 heat...
  11. B

    15mm flow and return, plate exchanger blockage?

    The combi boiler has 22mm flow and return outlets but they are immediately reduced to 15mm as they come out the boiler. After the pipes come out of the boiler, they split off into 3 branches. Branch 1 is for a single radiator only. Branch 2 feeds about 9000BTU diownstairs and branch 3 feeds...
  12. B

    Fittings to branch into cast soil pipe?

    I would like to add another WC about 2m to the right of existing WC. The existing soil pipe has only one WC (coming out the wall straight into the soil pipe) and is a straight vertical cast iron 4 inch pipe with a vent at the roof. My plan is to go out the wall with the new WC and then go down...