Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. A

    What to replace a Salus RT505TX with?

    Our Salus RT505TX seems to be failing according to Salus as the battery low icon won't turn off even with a reset. It was fitted 7 years ago with a Worcester Bosch boiler, the boiler is fine and we hoped the thermostat would last at least as long. They suggest a RT510TX/RF but we are looking at...
  2. A

    burying gas supply pipe

    The gas meter is outside the house on the side wall, we want a gas stove at the opposite end of the house so our plumber will run a new supply from the gas meter area along the front wall of the house to the opposite end, it will need to be buried. What depth should it be as we could dig the...
  3. A

    flushing out a system

    I had a WB 440CDi fitted 2 years ago, it was serviced again last May and a service due now. We took the hall radiator off last week to have the wall plastered, I isolated it by turning off the TRV & lockshield valve. When I drained it a lot of black water came out which I guess had been sitting...
  4. A

    are Screwfix 15mm isolation valves non leaking at the screw?

    I need to replace a 15mm iso valve as it leaks from the screw. Are the Screwfix ones reliable does anyone know?
  5. A

    fitting a check valve to a 25mm MDPE outside supply spur

    I've want to take a spur off the short section of 25mm MDPE pipe going into the house just just after the stop tap. It's to get full pressure for the outside taps otherwise the 15mm pipes snake all the way through the house to the outside tap. The question is what should be done to comply with...
  6. A

    capping off unwanted central heating pipes

    We had a new utility room built and planned to put a combi boiler on the wall. The existing 22mm central heating pipes from the existing WB floor standing boiler in another part of the house, were extended to suit the new position and 22mm capped tails were left sticking through the ceiling. We...
  7. A

    tall radiator not heating

    I replaced a Stelrad with a tall rad in the bathroom but it's not heating up. The only difference in pipework is that the existing 15mm copper is extended by 800mm 10mm tails to the new rad position. New rad is full of water, Boss dual flow TRV one side and lockshield the other. The old rad...
  8. A

    30Kw v 35Kw running costs

    Will a 35Kw boiler use a lot more than a 30Kw? Only two bathrooms in 4 bed house but need a good hw flow to fill a bath each day.
  9. A

    15x15 tap flexi with valve?

    Anyone know where to get either a 15x15 braided flexi hose with valve or a 15x10 or a 10x10??
  10. A

    continental type 10mm pipe fittings

    I'm re-fitting a bidet and basin. The bidet had 15mm pipework which was bulky and awkward to fit, I want to fit service valves this time with flex connectors up to the tap tails, 15mm will take up too much space. I've just come back from Menorca where they use really neat connectors which I...
  11. A

    The wisdom of fitting natural gas boilers and onward costs/RHI

    I posted a couple times about fitting a new gas boiler and would like to thank all who responded. To re-cap I need a new boiler as the WB Heatslave is v/reliable but 20yrs old and probably only about 60-65% efficient. Until today I was thinking Veissmann Visodent 30Kw, but I had a visit from a...
  12. A

    which make of boiler is best?!

    Re my other post about Viessmann boilers I have now spoken to three plumbers who fit a lot of boilers and each one recommends a different make, first said VM best as WB are not as reliable as they were, second said Valliant, third WB. For someone not in the know how do we decide which one to go...
  13. A

    costs for fitting a new Viessmann boiler

    I got a price for fitting a new boiler but would just like opinions on whether it's about right. The new boiler will be a wall mounted Vitoden 100 30Kw, the work involves;- 1) cut off the gas supply at the outside meter to the existing floor standing boiler in the kitchen. 2) run 12m of new...
  14. A

    which water softener??

    Can anyone recommend a water softener that can be fitted to the rising main that will cut down on limescale in kettles, pipes etc? I'm not talking about the magnetic type of water conditioners though. Iv'e looked through a few of the previous posts but can't see any mention of specific...
  15. A

    service valves in central heating system

    I want to isolate the heating system at one end of the house and have fitted two service valves into the 15mm flow and return, just wondering if this is ok. There are 4 rads that are isolated. The valves restrict the flow a bit but will this be a problem when the valves are opened again to...
  16. A

    will one way valve cause pressure drop

    I'm running a new supply to two outside taps but rather than having bib taps with non return valves, I got them without and plan to fit an inline NRV in the utility room where the cold water supply is to be intercepted. One tap is about 4 metres from the valve, the other is down the garden about...
  17. A

    connecting a remote water supply to garage

    I need to lay on a new supply to an outside tap on the house wall, and another which is about 30metres down the garden by the garage, the blue 25mm MDPE pipe run has already been buried in a trench leaving both ends sticking up, and a spur T'd off for the house wall tap. The house end is right...
Back
Top