Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. M

    02 levels 20.6 on air intake on flue yet misfire on Worcester boiler

    The boiler giving a put put sound on ignition i,m sure you will have the answers.:smartass: By the way its been rectified
  2. M

    Connection to a gas pipe that:s 50 years old

    New gas meter ,no pressure drop, 3/4 imperial copper pipe which goes under a concrete floor to a free standing cooker approx 3m pipe run which comes out the floor in 3/4 copper ,pressure and gas rate fine.OAP has bought new free standing cooker and wants it fitted. NO pipe work to any other...
  3. M

    high flue gas temperature readings of 90oc on Worcester 28i condensing boiler at full

    in service mode and boiler on max the flue temp goes way up to 90c all other reading are ok . i rang Worcester and they said it was ok but i wonder if its the towel rail first of the boiler causing the high temp no thermostatic just lock shields. in hot water only mode tap full on its 68c...
  4. M

    Pressure relief valve

    Hallo just after some advice and your thoughts on this one. Yesterday went to service a condensing combi and i have to say it was a very good installation in a flat above a shop . However they have run the prv pipe into the internal vent stack just above the condensate pipe is this a no no or is...
  5. M

    gas cooker with no high level grill but free standing

    460mm from top of hob to bottom of unit can these dimensions be reduced if the wall units are set back away from the cooker by 200mm :mad:
  6. M

    3 pipe shuffle

    How would you run 3 pipes horizontal above a concrete kitchen floor ie at skirting bd level. Would it be gas bottom hot next and then cold :D just flirting with the young ha
  7. M

    first time i have fitted a Worcester boiler

    Hi iv just fitted a Worcester 24i junior and the gas rate of 2.59/m3h seems a bit high to me.;)