  1. M

    Does anybody know of a place that does training on agas

    As above really any body know anywhere that does training on agas? I turn down quite a few and want to start working on them. Aga themselves wont touch you unless you work for one of their companies and I cant see them subbing to me when I have no experience on them.
  2. M

    DIY Forum for DIY Plumbers?

    I think if you removed the diyers it would be a ghost town in here and would be the end of the forum. Who will visit a forum with no new content. We have the arms and gas safe only for anything we dont want the customers to see or read. Maybe try and build the arms back up to the way it used...
  3. M

    Gazebo for external work

    Any body use a gazebo type thing for external work? More thinking of oil installs. I want something fairly hard wearing as it's got to with stand cornish wind and ideally have sides to it.
  4. M

    Firebird slimline combi

    Never installed one cant fit the grant combi in so thought I would price for a firebird. Are they any good? I'm not a big fan of worcester oil and dont think they are worth the extra £400.
  5. M

    Vertical flue through 4 pitched roof

    How do you go about putting a vertical flue up through a roof where you cant get a roof ladder to hook over anything. They have a vertical flue in now and it's on a pitched roof but a side one if you get what I mean. I'm guessing scaffold up then unsure what to do next.
  6. M

    Nest with oil combi compatible?

    I wired up a nest with an oil combi and whilst the heating side works fine is the hot water side compatible? It seems to me that it doesnt work with an oil combi so I just turned it off. Am i right or wrong.
  7. M

    Gas engineer software glitches

    Anybody else having problems with it? Just tried to convert a quote to invoice as I have loads of times and its deleted everything on the quote! :mad: I've had numerous times I cant open up invoices and it seems to lose things from time to time. Getting pretty fed up with it at the moment.
  8. M

    Anybody installed an alpha e-tec

    Got one to fit in a couple of weeks wondered if anybody had fitted one and what they are like to fit?
  9. M

    Can you fit any pressure reducing valve/ multiblock on unvented.

    Assuming the pressures are the same can I fit a standard pressure reducing valve/ multiblock or do I have to fit manufacturers specific? At the moment i have a grant duowave with a megaflo multiblock but the block is leaking the grant one I can get in a couple of days but I can get a standard...
  10. M

    Have worcester spares jumped up in price?

    Following on from the debate about giving customers to worcester for fixed price repairs. Have they upped their parts costs quite dramatically recently? I know I stopped working for myself for a bit so didnt take notice of the spares prices but now the prices seem to have jumped dramatically...
  11. M

    Boiler plus on oil question.

    I've been asked to quote for an oil combi which I dont do very often. What do I have to do to comply with boiler plus? Is it just fit a smart programmable stat like a nest? As obviously weather comp doesnt exist for oil does it?
  12. M

    Any Ferroli optimax he plus 31 c gods on here?

    I have above boiler with A41 flashing up flow sensor disconnected. So i have checked for loose wires pcb end and sensor end. I have checked the ohms on the sensor both sides and got 11k on both that was both through the wiring loom and straight onto the connections. Which says to me that there...
  13. M

    Rf cylinder stat? Has anyone used one are they good?

    I have a job at a b&b that the water is apparently getting scalding. It has an old oil boiler and the hot water is on gravity. I've been out before and the cylinder has been changed not too long ago and has not been installed brilliantly. My only thought is to convert it to fully pumped but...
  14. M

    Oh do I hate Worcester!

    Went out to a leak on a Cdi. Armed myself with an o ring pack whipped the plate out and found the diverter rusted and a small amount broken off. So new diverter valve needed grab another and out comes the old spend a good 5 minutes cleaning up the cold inlet so it's sparkling clean put it all...
  15. M

    Flashing burner light on vortex pro combi 26e

    Anybody know what the flashing burner light means? Tried to find any fault codes can't find any. I think the pcb is faulty but want to double check before I fit one.
  16. M

    Thermal imaging camera

    I've got a customer who has a leak. I've checked and double checked all the main culprits but no joy as they have karndean flooring throughout I even tried leak sealer (not a big fan of the stuff myself) Its a wooden floor and all the pipes run under it I was wondering if a thermal imaging...
  17. M

    Moving oil boilers in this case a combi

    How do you lot move oil boilers around I've got to fit a combi next week and not looking forward to shifting it. I've got a sack truck up to 200kg but it never used to feel too sturdy under a heat only let alone 160kg of combi boiler. Naturally everytime I get an oil boiler I strip all the...
  18. M

    Boiler grants

    Anybody know how to start carrying out grant work replacing boilers. I've had a few companies offer me contract work but I don't want to do it for £200 or so a time. I've had a google but all I can find is the companies that carry them out and nothing about how you become an installer.
  19. M

    Power flush machines

    I am after a cheap power flush machine. The reason I am after a cheap one is I don't use them a huge amount due to the water around here. So what are half decent?
  20. M

    Price per meter

    How does every body charge for pipe do you charge a certain amount per meter or do you work out exactly how many fittings and charge that way. I was thinking of charging a certain amount per metre and have that cover fittings and clips etc just not sure how to go about it.
Back