Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. S

    Vaillant and Glow worm flues

    Are the vertical terminals for glow worm and Vaillant the same / interchangeable? Does using one brand with the other constitute a breach of Mi's or regs?
  2. S

    Analysing a Logic.

    If you are ever analysing a logic and get rediculously low co then the sample point tube probably looks like this inside. And un-twisted
  3. S

    Potterton performa flue

    Came across this Need to know if Potter ton performs flute parts can still be had or if modern high efficiency potterton/baxi flutes are compatible/interchangeable. Have shut Boiler off its not leaking co but it's producing stupidly high Parts per million. The roof terminal looks like it has...
  4. S

    Secondary return pump control.

    I am fitting a secondary circulator and looking for the best way to control it with a single channel. Programmer and pipe stat/s. I am aware of the grundfoss comfort but it's pretty big money. How have you guys set them up in the past? Dont want to time it alone but not sure how best to set up...
  5. S

    Colleague looking for help with a glow heap head scratchier.

    A good friend and fellow gas engineer of mine who is not currently a member of the forum (at least not with gas safe private forum access) has been to a British gas 330+ / Glow worm (not a hxi this one has an aluminium heat exchanger). The Boiler has an Ignition fault, when firing the burner...
  6. S

    Low loss header system design.

    Anybody know a good source of information pertaining to best practice with a low loss header based heating system. I am taking on my biggest single house install to date and much of the design of the system is new territory for me. The building is listed 3 storey with open fires in most of the...
  7. S

    Waterfall mixer cartridge replacement.

    Anyone ever changed one of these or similar? Pic to follow when tappatalk lets me upload the image.
  8. S

    Korean gas main explosion.

    Kaohsiung 'Gas' explosions shake Taiwan city - Ju…: Kaohsiung 'Gas' explosions shake Taiwan city - July 31, 2014 - YouTube
  9. S

    Honeywell gas valves

    Need a honeywell vk4105m 5132 4 gas valve for a ferroli domicondens f28 can anyone on here tell me if the valve differs from the core vk4105m and do the trailing 5 numbers indicate the difference. Essentialy can any vk4105m be used as long as tge connectors/ pipe unions are retained from the...
  10. S

    Ferroli domicondes f28

    Been to 1 of above this evening locking out on a10 no ignition. Believe gas valve is goosed as solenoid resistances were out. Concerned that the pcb appears to spike voltage up to 1000volts. How is this possible? Tried 2 multimeters got the same reading. Its not for long but briefly when the...
  11. S

    Anyone worked direct for Baxi group before?

    I have a friend who has just been to an interview and has been deliberating leaving working for himself to work for Baxi group. Assuming he is a successful candidate, are there any pitfalls he should be aware of or any first hand experiences from other employees out there on the forum good or...
  12. S

    Replacing siamp skipper 45

    Fairly certain the fault lies with the valve seat letting bye as replaced washer and still leaking in to pan. Cistern is siliconed to wall but have resogned myself to taking the whole thing off. Interested to know what flush valves (drop not syphon) you guys would recommend. I have seen...
  13. S

    In screed fitting/valve access box.

    Does anybody know of anything that would work as above. Ideally inexpensive and readily available. I need to move a brass stopcock on mdpe from the center of a kitchen unit back to the wall. I can cut the 50mm duct back and break a small trench in the screed and then go from mdpe to copper with...
  14. S

    Glow worm 18 sxi fault f13

    Have been to see the above today. Have tried disconnecting thermistors overheat fan and gas valve and have tested resistance and continuity of the loom. The fault persists is there anything anyone out there knows causes this or causes the PCB to fail with this error. Disconnecting the fan caused...
  15. S

    Worcester greenstar Junior 28i possible leaking hex.

    I posted about a week ago regarding my own boiler (the above) not fitted by me as I cant stand Worcester boilers. I suspect the hex is leaking as boiler drops pressure even with service valves closed. I have had it off for a good day now have topped it up twice to around 2 bar and the pressure...
  16. S

    Worcester primary hex leaking?

    I read a thread today that had a couple of members saying they have come across lots of leaking worcester hex's whats the best way to check im thinking isolate the boiler and leave the sump cover off tgen check for pressure drop and water in the sump? I am the unfortunate owner of a Woosy Tosch...
  17. S

    Washing machine valves. Why oh why.

    I hate washing machine valves infact any cheap 15 mm issolating ball valve. But particularly washing machine valves. They are so bad they are almost not fit for purpose. Often not enough 3/4" thread to bottom out and seat the appliance hose. Or they do have enough thread but once home you can no...
  18. S

    Glow worm 70ff micron 2000801991 pcb

    The above pcb is always listed as supplied with TPO. What is a TPO? What function does it serve?
  19. S

    Salus mp100A pump error code

    Has anybody come across an E5 error code on the Salus mp100A pump? The manual kindly lists faults for all error codes from E1-E4 but not E5.
Back
Top