Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. R

    Baxi solo he overheating and fog horn noise

    boiler goes to overheat lockout if you let it cool and press reset it works for 15 mins then locks out again, it also makes a noise like a foghorn for about 5 to 10 seconds at ignition i have checked all limit stats all are ok also replaced the combustion door seal, cleaned the burner it does...
  2. R

    Worcester heat exchanger baffles

    Went to service worcester 18 ri found the casing red hot the burner seal had gone so decided to do a strip down service as the fan pressure was -4. Removed fan bum, burner, top baffle but could not get bottom baffle out was on with it for 3 hours tried bicarb and water as Worcester said this...
  3. R

    Vaillant f75

    Hello heating gods I am a Vaillant approved installer and until lately have considered Vaillant to be the best on the market this week I have had 3 boilers go down with f75 Vaillant say its sludge but one of the boilers was only installed in September, when we install our boilers we do a power...
  4. R

    Government free boiler schemes

    I am hoping somebody on here has some information on how to get some work from the free boiler schemes not sub contracting but getting registered to do it freom start to finish ie eco & greendeal also anything else or is it not worth it would be good if we could all put the info we have on one...
  5. R

    Vokera Compact solid red light

    right lads will run you through this boiler of my customers bit of a head scratcher plumber before me changed main ntc sensor not the hw sensor i have been told both need changing at the same time is this correct? day 1 called out prv running filling loop had been left open to keep the heating...
  6. R

    Anyone supply an idiots guide to DIY powerflushing

    powerflushing against mains cold powerflushing has a better flow rate powerflushing does not dilute the chemicals this is most important maybee the first rad will be ok with mains but after that all your cleaner will be washed out
  7. R

    main combi eco

    Went to a 1 year old main combi eco today as it was loosing pressure upon inspection found the condensate to be just ran under the floor in the bungalow who ever fitted it even had the condensate coming out of the floorspace into a gulley but the two were not connected really bad anyway the...
  8. R

    Vaillant turbo max plus 824 E dhw problems

    Coustomer called me out today as dhw was running hot cold hot cold boiler was showing no faults so replaced the plate heat exchanger but problem still is there tried changing ntc sensors around still happening any thoughts would be greatly appreciated. Boiler does not seem to be modulating does...