Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. R

    Keston C25 fault

    Hello All Just stuck on a C25 keston , wondered if any of you have come across the problem. The boiler seems to be doing everything except firing. It goes all the way to ignition and gas valve opens up as I can smell it but its not firing. What am I missing. Help much appreciated.
  2. R

    Not getting pump over run on y plan

    Morning Fitted a Vaillant 637 on a Y Plan, It has santon premier plus unvented tank and a new Honeywell ST95 a two channel programmer. Everything seems to work correctly as in when the demand for hot water or heating is requested the boiler fires. But as soon as if you turn it off from the...
  3. R

    Any recommendation on Mains Hot Water Supply

    Any advice on a mains hot water cylinder without the need of discharge pipe. Have to replace one where there is no provision for discharge pipe. Have found one Gledhill BoilerMate BP Mains Pressure Hot Water Thermal Store Cylinder, are they any good. Any advice much appreciated.
  4. R

    Bronz Pump

    Hello All Can any one please advice on a decent Bronz pump. I need to fit one on a third floor flat, where the set up is bit strange, the hot water tank supply is through 2 unvented tanks fitted parallel in basement. The distance is approximately 30 meters or so from the tank to the flat. The...
  5. R

    Potterton Powermax HE 115

    Hi All BG have capped off a potterton power max HE 115 due to leak from flue collector behind heat ex changer. Below is the pic of what it looks like. Has any one come across this before. Was there yesterday, the custard of instead of capping the meter had cut the pipe and capped off within...
  6. R

    Jaguar Boiler

    The customer called saying the boiler wouldn't fire and its displaying F1 code. Went there and the lead for the ignition was loose or probably had a dry contact, any ways cleaned and re-connected and the boiler fires The boiler works fine on the heating mode but on hot water its making aloud...
  7. R

    Ideal Elan 2 RS 40

    Any one of you would have any idea where can I get hold of gas valve on this boiler it is a very old one. The part number is 004050 if that helps, I have rung number of stockist but no luck. In case if any one is taking of an old one I might travel a decent distance and pick it up. The Customer...
  8. R

    Ravenheat White Star 24 T Fault

    Hi All Been to a ravenheat combi boiler yesterday, nothing was happpening initially i.e. the pump would run but fan not moving a bit, no voltage coming on the fan, checked on PCB nothing there as well for fan, replaced PCB and the fan works now. The boiler isn't firing at all, neither on...
  9. R

    Can I return an ordered boiler?

    Hi Been put in a tricky situation today. I had ordered a bolier for a customer from a supplier but due to miscommunication the customer did not purchase the boiler from my supplier as I had advised but went and bought the same boiler elsewhere. My supplier was not to happy about this and...
  10. R

    What are the dangers of using 15mm gas pipe on Condensing boiler

    Just been to a property today and the the boiler has 15mm gas pipe, The boiler has been recently installed its a Vaillant ecotec plus 24. I need to let the landlord know, but don't want him to think I am trying to pick out mistakes on some one else's installation. Would appreciate list on...
  11. R

    Symptoms of faulty Gas meter

    I was called to a property today, where the customer complained his bills have been very high in the past couple of years and the consumption has been very less. Went there did the tightness test, no leaks. Standing pressure (SP) was 27.5mb on the meter and 26mb on the boiler nearest the meter...
  12. R

    Boiler on the third floor

    I have to install a boiler on third floor of a house, the boiler is going on the kitchen wall and the excess to the outside wall is very tricky and hence I am terminating the condensate and PRV pipe internally in to the waste pipe. I am planning to use a tundish for the PRV pipe and a trap where...
  13. R

    Sealed system on a open flue boiler

    Can an open vented heating sytem be converted to a sealed system by adding an expansion vessel on a open flue boiler. As the boiler does not have a over run heat stat. Will this be right. Any advice would really appreciate. Thanks in advance.
  14. R

    Valiant 310 ltr unvented and Worcester Boiler

    Went to customer's house yesterday, was told they are having problem with hot water. The unvented tank is located in the loft, its a 310 ltr Vaillant tank. Heating is working fine. The boiler is located in the utility room downstairs. Had a look at the boiler not close enough though, flow and...
  15. R

    What Underfloor Heating Boiler

    What boiler is the best for underfloor heating for an area of upto 130 sq.mtr.
  16. R

    Combi with Storage tank

    Is it possible to put hot water storage tank on a combi boiler i.e. if the hot water tank is installed after combi and from the tank to the taps.