  1. D

    Hard water filter for shower

    I have just had to replace a Wickes electic shower; the new one is a Mira Sprint multifit. The installation instructions say that a water treatment device is required if water hardness is over 200ppm; otherwise the guarantee will not be honoured. My water is rated a Very Hard, so I guess it's...
  2. D

    Boiler not getting hot enough

    We moved into our current home in June. The heating is supplied by a 10 year old WB Greenstar CDi 37kkW combi boiler. I had the boiler checked by a local GSR engineer who has serviced my son's boiler for many years. He said it was working correctly. So far it has worked OK, getting the house up...
  3. D

    Boiler advice needed

    I moved house three weeks ago and now, for the first time, have a combi boiler - it's a WB Greenstar 37CDi. Among the documents given to me is a Service/Maintenance Certificate dated January 2019 whichsays that the boiler is safe to use. Attached to it is the output from a FGA which gives these...
  4. D

    Heat loss from pipes

    Many heatloss calculators make an allowance of about 5% for the heat lost from uninsulated pipes. So, in my case with 13kW of rads there would be 650W lost from the pipes. If you search for "heat lost from uninsulated copper pipes" you will come across a lot of info on the subject. But they all...
  5. D

    This is why we will not endorse DIY gas work!

    I doubt if the elderly couple have the money to pursue him through the courts but, hopefully, they are well insured and their insurers will pursue him. However as he is probably a "man of straw", i.e no assets, even the insurers may give up. Do you think he is even insured?
  6. D

    How old is my Grundfos pump?

    I have a Grundfos Selectric 15-50, which looks similar to the current version but with one significant difference: the speed control knob is white and the numbers are on the flange of the knob and appear in a slot cut in the black surrounding. The only numbers I can see are:983484 and U327...
  7. D

    Drain valve problem

    I am trying to drain my system but am having problems with a leaking drain valve. It looks similar to the left picture; there is no knurled nut as in the right picture. The problem is that, when I undo the square headed stopper, more water is coming out round the stopper than through the drain...
  8. D

    System Boilers

    Is it possible to use a System (i.e sealed system) as an Open Vent Boiler? The pressure gauge would obviously read zero, but it there anything which will prevent it working?
  9. D

    DIY Central Heating Installation Advice

    One thing you obviously have not taken into consideration is: what happens if something goes wrong? If you buy the boiler and it then turns out to be faulty the GSR who installs the boiler can legitimately say, "I didn't supply the boiler so it's not my problem guv. You'll have to get in touch...
  10. D

    DIY Replacing Radiators

    Don't waste your money on a course. I learned all I needed from library books; there are plenty in Croydon libraries - I used to borrow them. The £300 you save will then go towards the cost of the rads and any other bits you need. You can also get plenty of free advice from this forum, so here...