Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. G

    greenstar 35cdi problems

    Boiler had an F0 fault code which turned out to be the pcb. However after changing the pcb which came with the wiring loom it will now not do anything. Display is d3 and the blue led is flashing. Any ideas? Found on line info was Terminals 8-9 not detected at connector ST7. This pcb has no ST7...
  2. G

    Vaillant eco TEC 831 combi hot water problems

    Got an 8 year old eco Tec 831 and the diverter was letting by so I changed the diverter to still have the same problem. Then realised the motor was not pulling the pin outwards when energised so have replaced the motor too. The problem is the motor makes all the right noises but not pulling the...
  3. G

    Worcester boilers

    Is it just me or are these boilers a pain to service and repair. Had to replace the PRV on a Junior greenstar 28i and it was a nightmare to replace. Even testing a GV the plugs are on the back so needed to be removed to check solenoids. Does doing their training course help at all? Would be good...
  4. G

    Alpha combi boilers

    Went on their training course last year and all seems good but still not fitted any. What is your opinion on them guys? Also do you think the commissioning of them is a bit long winded? I am currently fitting Logic plus and Vaillant boilers but Alpha prices are looking quite good for the low end...
  5. G

    Grndfos pump numbers

    I have a UPS 15-50 x18 pump. Can anyone tell me what the x 18 stands for?
  6. G

    Water softener on megaflow system

    The system has 3 showers, kitchen and cloakroom. Question is can most water softeners cope with demand if most were running at once? Also are some softeners more up to the job of this demand? Most say the timer models are not the best but twin coil units are the best?
  7. G

    potterton netaheat mk2 16/22

    Removing this boiler tomorrow for replacement it has 5 core flex connection. Does anyone know the wiring of this old boiler for easy transfer to the replacement?
  8. G

    Heat only boiler recommendation

    Cust needs 18KW boiler, heat only and they like Baxi. Problem is the solo has such a bad name although I have fitted a few with little problem. Normally would go for a vaillant 418 but they are not liking the price. Any thoughts on a reliable easy on the pocket boiler?
  9. G

    Rothenberg pipe freezer

    Does anyone own one of these and what's your verdict on performance. Thinking of getting one
  10. G

    Potterton main 18he heat only

    boiler runs fine on start up till heat satisfied, then trips out ignition fail on light sequence. Red light on and right hand green light on. Re set all ok till next restart, gas valve fine and spark generator working well. Any ideas out there on this one?
  11. G

    Flow hammer on 3 port honeywell valve

    Problem only occurs when HW and CH on demand then CH satisfied. Hammers for 2-3 secs on mid pos shutting off heating. All other options no noise at all. Netatec system boiler and the cylinder circuit is still 28mm off original gravity run, with manual vent at the cylinder so no trapped air. Any...
  12. G

    Potterton gold combi E168 fault code

    Have a customer with this fault code and they have to re-set often. Looked it up in the manual and no mention of it. Any ideas guys?
  13. G

    Ideal logic plus

    What do you guys think off these boilers? Have fitted a few over the last 6 months and found them great in fitting, size and price. ( also 5yr warrantee ) Not had a single problem so far, my only concern is no stainless steel heat exchanger.:shocked3:
  14. G

    Ignition problem main 24he band b

    hot water working fine. On central heating the burner lights for 1 second then goes out, after the usual 3 attempts it goes to ignition lock out. Told low pressure setting on the GV could be wrong will check this out. Any other ideas if this does not work tomorrow
  15. G

    Main 24 he band B combi

    Still got problems great on hot water, on heating burner lights briefly, 1 second then goes out, 3 attempts and it shuts down on ign. Reset and it does the same, but hot water instant ignition . Any ideas?
  16. G

    Salamander Mains pressure booster

    Are they any good? has anyone fitted one
  17. G

    Main 24he band B flame failure

    Had a problem today I couldn't solve. boiler works great in hot water mode. On central heating it sparks to light but burner only just lights then goes out after the usual 3 attempts it trips out, any ideas please