  1. D

    Install teams required

    Install teams required, we have ongoing social housing and council install work. the majority of the work is in Cardiff and the surrounding valleys. We fit either Valiant Pro 28s Valiant 618 plus or the new worcester 25i and 30i boilers depending on the client. We would require you to have...
  2. D

    install teams required in Cardiff and surrounding valleys

    Install teams required, we have ongoing social housing install work, the work is a mixture of full hits ( boiler rads and pipework) conversions ( boiler keeping existing pipework and fitting new rads as required) and combi swaps. The work could also include vertical flues and condense pumps...
  3. D

    meter bank

    ive fitted 7 boilers in a HMO the building had a new meter bank installed to facilitate the new boilers, the bank is all fed off a single pipe which then ts off to each meter ecv. 5 of the meter boxes had been installed befor i got there and the three remaining boxes were empty. One meter box...
  4. D

    Ideal isar he 35

    Just been to a callout on an ideal isar he 35 leaking from the back of the boiler where it would appear the expansion vessel is mounted, I've never worked on one of these before but it would appear to access the expansion vessel the boiler needs to come off the wall am I right in thinking this...
  5. D

    baxi duotec 28hea

    Ive diagnosed a faulty three way valve on a baxi duotec, its also leaking from the dhw temp sensor. Ive had to buy two parts one with a bypass and one without as im a dingbat and didnt take pics, the parts guy didnt have a washer pack for the valve, so im wondering if the dhw sensor washer is...
  6. D

    vaillant vertical flue

    Hi guys im after a bit of advice, im fitting a vertical Flue to an ecotec plus831 and cant find any guidance as to required distances from a ridge vent type flue, Im thinking for some reason 1500mm but I cant find any guidance to back that up. In the MI it doesnt give a figure for this scenario...
  7. D

    Need to buy a Power flush machine?

    I am going to be working on a contract that requires a powerflush on every job. Ive never owned one or in fact used one. Can anyone point me in the right direction of what and where to buy? and how would you guys go about using one on an install job?:confused:
  8. D

    alpha intek 28x

    Fitted an alpha intek 28x today should have been a straight forward combi swap, it took 7hrs. The Flue connections were awful, the pipework was not the standard f hw g cold r and I couldnt get the zone valves and salus unit to wire in and work. Ended up sticking a standard room stat on and...
  9. D

    Part L

    Having got hacked off with service and repair, I have been looking at getting into installations but everything that comes up contracting wise, needs Part L, its only a day course but I cant seem to find one before september. Anyone know where I can get it quick smart?
  10. D

    ideal boiler, unvented, heating but no hot water. Two Port Valve??

    A relative has called me, stating she has an ideal boiler (not got the model yet) on an unvented system that is firing for heating but not hot water. Im thinking two port valve, anyone got any input, before I go there and tell her to fit a combi as I understand them better lol, I have got G3...
  11. D

    Ariston microgenius 24 mffi

    Went to a repair this morning on an ariston microgenius 24mffi, E34 error code showing, the cust had hot water only for a few seconds before the boiler cut out and the heating was only working at a low temp. I suspected sludge/debris in the heat exchanger and plate heat exchanger. I had replaced...
  12. D

    Ariston microgenius 24 mffi

    Went to a repair this morning on an ariston microgenius 24mffi, E34 error code showing, the cust had hot water only for a few seconds before the boiler cut out and the heating was only working at a low temp. I suspected sludge/debris in the heat exchanger and plate heat exchanger. I had replaced...
  13. D

    washing machines

    I went to a job today, following a visit from a retailer ( not sure which one didnt ask) who had installed a washing machine, on installing the machine he diagnosed insufficient water inlet flow and advised calling a plumber ie me. The existing cold feed was run under a concrete floor in 15mm...