  1. B

    Heating System

    Alright guys? I don't do much installation, mainly breakdown/service work, so forgive me. I've gone to look at a mates boiler, old baxi solo which is corroded through and needs replacing. I was thinking of fitting a baxi ecoblue 15 erp as it doesn't require a pump overrun and it has rear flue...
  2. B

    Commercial gas installation, domestic boiler

    Alright guys? I went to a property today for a boiler breakdown, easy enough to diagnose as a faulty gas valve. Problem is, the house it pretty large, it has a 35kw combi (used as a system boiler), another 40kw conventional boiler, an andrews water heater and an aga, all connected to a U16...
  3. B

    Procombi 100he fault

    Aright guys? looking at the above boiler for a friend. Boiler has a solid red fault light, MIs say thermistor fault, but all thermistors testing fine and boiler won't reset, even if turning power off. Fan also runs constantly with no demand. Checked all 3 ntc, overheat, aps, etc... And they're...
  4. B

    Oil boiler service/repair

    Alright guys? im being put through my oil with my new job. im just wondering if any of you guys do oil boiler service/repair. If so, what tools do you recommend having, obviously got your standard tools. Just wondering if there's any unusual/handy tools that could come useful and make life...
  5. B

    Toilet siphon

    Alright guys? i don't really do any plumbing work but a friend has asked me to look at his toilet as you have to pump the handle a few times to get a decent flush. So in guessing the siphon membrane has failed. my question is though, how do you size the siphon? Just measure the height of the...
  6. B

    baxi duotec hea

    Alright guys? There is 2 different part numbers for the pcb for these, whats the difference, if any? Cheers :)
  7. B

    Ideal Classic NF40

    Went to do a service on the above boiler today. I automatically assumed that it was on an open vent, so did the service, put it all back together but thought I'd check the airing cupboard anyway, and luckily I did. They had last year upgraded from vented to unvented and it's now a sealed system...
  8. B

    Baxi 105HE high emissions

    Getting high emissions on a Baxi 105HE, a full strip down has been carried out but then found that the secondary heat exchanger seal behind the plastic connection had failed and was leaking condense back in to the boiler. So, I replaced the entire secondary heat exchanger today but still...
  9. B

    Worcester Bosch

    Alright guys? Not about a boiler this time. I'm just wondering if anyone works for Worcester or knows someone who works for them. I'm thinking of applying for a job that has just come up with them, but want to know some further information about the role. Cheers!
  10. B

    Leak from bath waste

    Alright guys? I don't really do any plumbing work but my mate has a leak from the bath waste. I've tried to remove it all to try and reseal but the plug part of the waste is stuck solid with silicone and the bath is quite thin so don't want to put too much force on it and end up breaking the...
  11. B

    Cooker connection

    Alright guys? i went to service a boiler for a customer yesterday, she had just had her whole kitchen done out and had a new range cooker. The guy who installed it put a angled wall plate and an angled bayonet socket on and the range won't push back to the wall, there's about a 2inch gap behind...
  12. B

    Glow-worm Energysaver Combi 2-100

    Alright guys? Any of you experienced with the above boiler? I went to service the boiler and discovered that there was a hole in the back of the heat exchanger and it had melted the all the insulation around the store. One of my colleagues went back and replaced heat exchanger and the store...
  13. B

    Ideal Isar

    Alright guys? Went to my mates boiler as he wasn't getting hot water and the radiators were warming when running the tap, so went and fitted a new diverter valve, the old one was jammed solid. Anyway, I was rushing the job as I had somewhere to be, and ended up putting the valve in the wrong...
  14. B

    Downstairs radiators not warming well

    Alright guys? A mates parents are having trouble with their radiators down stairs. The boiler is a Baxi Combi 80HE, I've changed the pump and balanced the system, but the problem is the same. I think the pipework is undersized so not getting enough flow, what do you guys reckon? The boiler is...
  15. B

    Electrics tripping when turning boiler off

    Baxi Bermuda, gravity h/w, pumped c/h. Whenever customer turns the boiler off on the clock the electrics trip. So I thought must be faulty switch on programmer, so fitted new programmer and tested but the same problem. Investigated further and found 106vac on the earth connection to the room...
  16. B

    Baxi Solo 3 4PF

    Got a flue to change on the above boiler next week. The flue exits on the right hand side of the boiler. Does the boiler need to come off the wall to replace or can you do it in situ? Cheers!
  17. B

    Condensate pump installation

    Alright guys? My mates condensate pipe keeps blocking, went around thursday and blew it all through and tipped water down it, but it's blocked again by today. I cut a section out above the floor boards as there is quite a few elbows, but no issue there, so I'm guessing the pipe is sagging and...
  18. B

    Ferroli Optimax Heat Exchanger

    Have any of you guys ever changed the main heat exchanger on one of these god awful boilers??? Had a right ******* doing it! The sump gasket is a tiny bit too small so need to stretch it over, but everytime you get over all 4 corners and let go, at least one corner would pop off! You need to...
  19. B

    Ferroli Modena

    Alright guys? looking at this boiler for my mate. no heating or hot water, light comes on with demand, pump runs with heating, but no fan. Checked thermistors and they were ok so checked fan a bit more, 0v between l and n to fan, 240v between l and e to fan, 240v between n and e. i think some...
  20. B

    Worcester flue

    Alright guys? went to a Worcester Greenstar zwbr 7-30 he earlier with a fan fault, 240v to fan but not working. but the flue is not one which I've usually seen on these boilers, it looks like one off a baxi, have any of you seen this before or know if it's the right flue? View image: image