  1. finchy01

    EP3002 no heating but hot water fine

    Evening all. I've not needed to post on here for a while but it's silly season again and one of my first breakdowns has me scratching my head a bit. EP2002 blown as was the pump which had started leaking. Replaced both, pump now runs when heating demand is present but it doesn't warm up. It's...
  2. finchy01

    Glow worm 30ci won't stay alight

    Afternoon chaps, I'm at a lose. I have just come away from a job wlempty pockets as couldn't fix the problem. Scenario. Glow worm 30ci combi won't fire. It sparks, fires on low flame but goes out after 5-10 seconds and then goes to F1. With all cases off right back to burner, it stays on. So...
  3. finchy01

    Balanced flue gas fire

    Morning all, a new customer has approached me asking for a balanced flue fire as there current fireplace has had the chimney removed. The only problem is there is a garage the other side of the wall. I've installed a few like for like fires but never a Balenced for our fan flue one. Do you know...
  4. finchy01

    210ltr horizontal cylinder in loft

    Evening all, just after a bit of advice. I'm due to carry out an install in a couple of weeks. Part of this is putting a 210ltr unvented cylinder in the loft. I've advised we need some some extra support. Beams are 600mm apart and the customer has asked if 18mm board is good enough. First...
  5. finchy01

    Potterton Netaheat Profile 60e

    So my fault finding has gone downhill over the past couple of years ad I haven't been doing much. I have the above, fan starts, pilot sparks then lights. I hear a click (like gas valve is opening) but then the burner doesn't ignite and it's got a slow continuing spark even though the pilots...
  6. finchy01

    Invented direct cylinder

    Morning chaps. I've just been to look at a "simple" job. Customer is opening a new shop and just wanted their sink moving from existing to new shop. Only problem is they only have mains water, no facilities to heat water (they didn't realise this) so I'm now trying to sort out a heater for them...
  7. finchy01

    Unvented cylinder D2 pipework

    Morning all. I'm quoting for a conversion from vented to unvented (I'm g3) a d the customer has said that she has been told that the d2 can go into normal waste pipe with a special connection. I was under the Impression that D2 pipe should be of copper material to the outside of the property...
  8. finchy01

    Pressure testers (advice please)

    I've never bothered with pressure testing before because my soldering is normally pretty good. I'm currently doing a full system from scratch though and the builder got all the materials. Bar the tails the whole lot is in barrier and I'm not happy with a lot of the joints. I have a horrible...
  9. finchy01

    Water hammer sound since new install

    Had a call back from a customer reported what sounds like water hammer early in the morning and evenings. Trouble is its an Unvented system and also only seems to be happening on the hot. I'm guessing it could be an expansion vessel issue but would be surprised as it's all brand new. My thought...
  10. finchy01

    Can anyone give advice on Hive wiring?

    As part of a job I'm doing the customers wants a hive fitted. I had a look yesterday but got confused. The current wiring in the programmer is L. N. NO to both hw & ch. Common to both linked into the L. The Hive has L. N. And NO & NC for both hw & ch. My question is where do I put the current...
  11. finchy01

    Which programmable stat do you guys rate?

    Evening chaos. A customer has asked for a hive whilst I'm at the property doing other works. I've not put any of these in before. She has an old Honeywell programmer at the moment which doesn't allow for HW & CH to be set a different times. I believe there's a Honeywell version too but I am led...
  12. finchy01

    Sentinal leak sealer on pressurised systems

    Afternoon all, Short and to the point. Have any of you experianced any problems using the sentinal leak sealer on pressurised systems? Think the leaks underfloor so want to try this before getting thermal imaging guys in. Thanks.
  13. finchy01

    Loads noise from expansion vessel

    I recently replaced a PRV on a cylinder that was letting by. I drained from the T&P valve and a little extra from the doc on the cold feed right before cylinder. I also repressurised the external exp vessel to just shy of 3bar as it was totally flat. I got a call yesterday saying that every ime...
  14. finchy01

    Commercial or not

    Here's one. If I service a domestic boiler in a pub. As long as gas pipe is 35mm or under etc how is this classed domestic or commercial? I only have domestic ticket so obviously wanted to check.
  15. finchy01

    Wiring problem?

    We recently installed some underfloor heating for a customer. I've not done it before so enlisted some help of another plumber friend of mine. Problem. Heating only = fine. CH and ufh= fine Ufh only = brings ch on too and can't be switched off on the room stat and rads get extremely hot. I've...
  16. finchy01

    2 questions.

    1) And I'm embarrassed to ask this but, what's the simpletons way of defining pressure and flow rate. Because I have a job with poor flow rate which gets a lot worse when 2 or more outlets opened but 3bar (it's an unvented system so I was surprised at the poor flow rate) 2) I'm getting 16ltrs...
  17. finchy01

    Wiring an old cylinder stat

    Evening chaps. I had to replace a danfos hsa 3 mid position today as no hot water. Also as part of it I also had to replace the cylinder star. Problem is I have no idea on the wiring on that and it was ancient with no wiring diagrams. There's l,n & pe. I was getting 240 on both l&n when...
  18. finchy01

    Wiring help replacing an old sun vic satchwell sm 3203

    I hate wiring. Never understood it, everytime I think I've cracked it I realise I'm completely wrong! Anyways. I'm sat on a customers landing twiddling my thumbs waiting for sunvic to call back so thought I'd post on here to see if you guys will be quicker! I'm replacing an old sun vic...
  19. finchy01

    Cylinder recovery time.

    Couple of quick ones I think. 1) How long from cold should I be looking at for full recovery of a standard cylinder? 2) How many litres does a 'normal' bath hold when full? I know both of these are a bit of a case of how longs a bit of string but it's just a rough idea. (I can tell see...
  20. finchy01

    Power tripping when dhw/ch demand.

    Evening all, I had a call back today from a month ago or so. The power trips when a) immediate demand for dhw and b) a few seconds after demand for ch. We replaced the programmer, cylinder stat and 3 port before (a different reason). This has only started a couple of days ago so I know it's...