Search results

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. M

    Who isolates the Gas when a property is repossessed

    As title really. I've had a couple of repossessions, when you get the keys as you know there is tape over all the services saying DO NOT USE and the heating, water and gas is off. Who does this? Is it the Bailiffs? If so I might give a few bailiff firms a shout and see what the crack is?
  2. M

    Ariston Microgenus 24mffii A01 fault. PCB?

    Hi guys. I've got an Ariston Microgenus mffi 24 non condensing that keeps displaying the A01 fault. Press 're set and it resets fine, fires up ok but the ignition keeps clicking, then after a while it will knock off again. It's like the boiler isn't detecting a flame as in the ignition sequence...
  3. M

    What's your opinion on this flue

    Hiya, just been and done a survey for a combi swap and came across this. It's a 4th storey flat, modern condenser going in obviously, customer is aware of the plume and is fine with it. I suggested running the flue along and out the canopy but the customer isn't happy with this. I'm quoting...
  4. M

    Combi swap with twin flue.

    Just been to price what I thought was a straightforward combi swap. The boiler that is in now however is an Ideal Isar with a twin 60/60 flue. It's a 4th floor flat, the flue is in a ceiling void with adequate inspection hatches. Measured the overall flue length as just under 6m. A logic has a...
  5. M

    Sime ecomfort. No hot water unless heating is on

    From cold with no heating on, open hot water tap, plunger comes out of diverter valve, valve meets micro switch, switch makes, pump runs then... nothing. Doesn't go any further than that. If the heating been on a while then warm water comes from the tap. Boiler doesn't fire though The...
  6. M

    2 port valve or programmer?

    Hi. I'm needing a bit of reassurance. I've had a long weekend, whilst enjoying my Sunday on the couch someone from around the corner called me to say their hot water wasn't working. It's an S plan with 2x two port valves. Heating works as it should on the timer and room stat. Hot...
  7. M

    Worcester Greenstar Junior 24i Plate Exchanger

    Hello. Im really hammering you with boiler breakdown questions at the moment :thinking: Worcester Greenstar Junior24i, get 3 mins of hot water then the boiler cuts out. I can hear the heat exchanger fizzing inside so Im fairly certain its overheating. If I leave the hot tap running then it...
  8. M

    Worcester 24i wont stay lit.

    I have a Worcester 24i on a job at the moment. It goes through its cycle, lights for 3 secs or so then goes out. It will then relight it's self and do the same again. When it re lights the cycle doesn't restart, it just sparks and goes. Electrodes look ok, APS seems to be proving. Time to look...
  9. M

    Baxi 105e instant problems

    Went out to look at a 105e instant earlier, Im normaly ok on these, I rather like them. However, this one whe I arrived had the fan light flashing, reset it and it fired up, fan was pulsating very erratically, and the flame was going up and down. I checked the voltage at the fan ad was getting...
  10. M

    Worcester Junior 24i Fan fault

    Went to one of these today. Sequence went: Demand > Pump > Dead, light flashing slow. Getting 240v at the fan during this sequence. Went off to get a fan. Came back, fitted it. Now I get: Demand > Pump > Fan... No ignition. Took the + pipe off the fan and blew into it. APS clicks and it fires...
  11. M

    More Breakdown Advice. Vaillant F75

    Got a 2 and half year old EcoTec Pro 24 showing F75 on CH demand. DHW is fine. Pressure differential sensor? If so where is it? Never worked on something so new!
  12. M

    glow worm 30cxi. no heating

    Got one this afternoon. Had a quic look yesterday DHW is fine. Nothing on CH at all. Gonna loop the roomstat out first. Any common problems to check next?
  13. M

    Main 30 DHW pin not coming out far enough

    Just short of the micro switch. What's normal procedure for this? I work a lot on these boilers, but not had this one yet. Diaphragm kit suffice?
  14. M

    Glow Worm Compact 75p not modulating

    Ive been to a Glow Worm that on both Heating and DHW will run on low light for 5 mins then go off. Took the Covers off, everything freezing cold. Got into the burner, all clean as a whistle, Fired it up for a sec with the covers off, tiny little flame on the burner just as I thought. First...
  15. M

    Fitting 2nd hand gas fires

    Fella has phoned me up, wanting a gas fire fitting, its out his sons house nextdoor "its only a few years old" and has the Manual. Its a Valour Legend. Not sure wether to entertain it or not. Not really keen on gas fires at the best of times, but Ive had far too many quiet days the past...
  16. M

    Faulty Ariston Micro Genus 24HE

    Hello, Im a new member to the forum, I am a Gas Safe registered business. Ive been called out to an Ariston Microgenus 24HE Combi, it displays an A97 fault code on both hot water or heating demand. The code in the book just says "electronic monitoring" Not much help. I did have the boiler fired...
Back