  1. J

    Gas pipe sizing spreadsheets or apps

    Hi. Can anyone recommend any apps/ programs/ spreadsheets for commercial gas pipe sizing. Thanks
  2. J

    Split large meter into six smaller meters. Who to contact?

    As above i have a customer who wants to convert from one meter supplying six flats to six separate flats. As i understand it this is done by the energy provider. Any other options? Their provider is extra energy. Spent two lots of 45 mins trying to get through to them and no joy so far. Grrrr...
  3. J

    Gledhill cylinder

    We've got a Gledhill 58x20 indirect cylinder to replace. The replacement Gledhill (1500x500) from Williams is almost twice the cost of the generic vented cylinder. Are they any better than a generic cylinder? Speaking to Gledhill it sounds like it's just the same size equivalent. Isn't...
  4. J

    Worcester rsf burner insulation burning.......

    Burner insulation was burning straight out the box. Stank and fga all over the place. Ends up brown front and back. Replaced twice with same result. Worcester looking into it and getting back to me. Ended up using some from one I took out.
  5. J

    BDR91 wiring in bathroom

    Hi all, Just wondering how people wire these. The installation manual http://www.honeywelluk.com/Documents/Installation-Guide/pdf/bdr91-instal-50034510-uk07r1009.pdf seems to have the wiring as Spur- BDR91-Boiler with power to the boiler getting passed through the BDR91 rather than...
  6. J

    Ideal training

    Just been to icos isar training day at ideal. Really enjoyable and informative. Also went to the logic training a couple of weeks ago. Having written them off due to bad customer service a while back I was impressed. Seem like a pretty good boiler. Nice to see how accessible most of the...
  7. J

    Auto air vent placement

    If anyone can give me pointers I'd be most grateful. I have flow and return coming in at the floor level in one corner of a room that rises to ceiling level runs around three walls and drops to the ufh manifold. It is drained at the moment but when I refill Id like to have done the most I can...
  8. J

    Press tool recommendations

    Hi. Anyone who uses pressfit tools for any recommendations? There seems to be a fair amount of choice so I was wondering how people found then in practice. Battery/ corded Ease of getting them into confined spaces. Ease of use etc. I've got Milwaukee m12 and m28 battery stuff if there's any...
  9. J

    Noisy icos

    Hi. Be most grateful for any advice from the learned. I've been to one of these that intermittently cycles with a very loud deep vibrating noise. Sounds respiration based. Does it with the front off also so not flue seals I'm thinking? Doesn't change if I touch/move fan. Flue. Condense clear...
  10. J

    Circulator replacement

    Got to replace a Grundfos alpha+ . Lots of choice it seems. Any reason to have one over another. Looked at the choice of an alpha 2l. Dab evosta. Wilo Yonos. And the flomasta from screw fix. Which looks exactly llike the Wilo. Thanks Jon
  11. J

    Intergas installations and service contracts

    Anyone had a letter from them about setting up service contracts with customers?
  12. J

    Legality of gas runs to flats through ground floor flat

    Hi, Was called to a five storey house converted into flats for a customer who is tanking his ground floor flat and has discovered the gas was run in copper and then buried under his flat. At some points it is just run straight in concrete. There is a need to rerun them all but I can't find...
  13. J

    Leak sealer is PVA?

    Just put some leak sealer in a system and I'm pretty sure it was just watered down PVA. Maybe it was because it was cheap off the bay? Didn't really fancy spending brand prices if they're all the same. If they're not then what works best?
  14. J

    Intergas DHW cycling hot and cold

    Hi, went to my first Intergas breakdown yesterday, having been on the website as a Platinum 5 installer for a week. :) Having been a Platinum 5 installer for a year :( Combi compact 36/30. The DHW is cycling hot and cold. Same outcome on both kitchen and bathroom mixer taps. Burner stays on at...
  15. J

    Heating zoned on a three port

    Hi. Went to a job where they wanted a new thermostat for the downstairs as it wasn't working properly. Having looked at the controls it was a 2 zone system where they'd used a 3 port to differentiate between them. Bizarre. Anyone seen this before?
  16. J

    Ideas for fitting a Combi where flue options are limited

    Hi everyone, I have to price a job and I have two options as far as I can see to put in a combi and run the flue. There is a window that takes up the whole of the external wall and so the easiest option for me is for them to take out the window and brick it up enough so I can put a boiler...
  17. J

    Gas seeker advice TPCP1A purging

    Does anyone know of any (cheaper) intrinsically safe Gas seekers other than a gasco. Needed for TPCP1A purging. Any advice greatly appreciated. Especially with all the love for the Testo and TPI gas leak seekers in the recent thread which as far as I can see don't measure LEL LFL % and/or...
  18. J

    Diy boiler move. Notifiable?

    Meant to say the form seems more set up for catching out dodgy installers than dangerous DIY. I may stand to be corrected it seems.
  19. J

    Diy boiler move. Notifiable?

    My next post was in response to your original post, before it disappeared into the ether. I was curious what you would have done. Shame I hadn't quoted it in the reply. Cheers Jon
  20. J

    Diy boiler move. Notifiable?

    Had contact from HSE officer asking for contact details for the house, whether it was being rented and a copy of the ID. Not sure I'll hear anything else back but would be good to hear what the outcome was. Cheers Jon