Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. RoryD

    Gas Engineer Software Price Increase

    I have been using Gas Engineer Software (trademark name) for a few years. I really like the app as it is a great aid for invoicing, books etc... The past couple of years the cost has increased. If memory serves is was £70, then up to £90 and this year to over £200! It's over a 100% increase...
  2. RoryD

    vaillant ecotec 831 S53 !!

    Boiler banging and crashing;Was able to easily stop the pump; found plenty of sludge residue in secondary Heat Exchanger. Fitted magnaclean, Magnacleansed system, replaced pump & 2ndary h/ exchanger. All fires well, heat circulates well. On DHW the water is luke warm 35ish degrees. Boiler...
  3. RoryD

    Main Eco combi 30 DHW Problems

    CH works ok. When there's a demand for DHW the boiler fires, modulates and then stops. The process then continues in this fashion ad nauseum. The flow pipe from the Heat exchanger doesn't get hot, the pump continually "surges" on/off and gets very hot. When the preheat kicks in the pump...
  4. RoryD

    Is Corgi Homeplan a viable Scheme to work on?

    I have an opportunity to do some work for this Corgi Scheme. Is anyone else involved? I'd like to know the Pros and Cons if any. Thanks RBD
  5. RoryD

    Glow worm Micron 50FF

    I have a customer who is really having some bad luck with his boiler. Over the past 2 years I've replaced 2 PCBs and a Gas Valve. There were other issues but not regarding the boiler itself. Tonight I have received a call about the boiler cycling on and then going off but both lights are...
  6. RoryD

    Vokera linea 7 DHW problem

    Bit baffled. fires up gets to temperature on DHW then cuts without modulating at all. I've removed and inspected the Secondary heat exchanger, water passes thru both sides ok. Can't find a resistance reading for the sensors dhw was at 9.7Kohms. At one stage I did get a 07 error (primary...
  7. RoryD

    Combi conversion and existing Shower pumps!

    Bit of a problem. Customer wishes to upgrade Potterton Flamingo for a Worcester Combi. She has a Salamander pearl 70 twin shower pump. I've highlighted the issue regarding water flow and that it may not be possible to achieve as good a flow with a combi. Didn't have a flow cup so couldn't...
  8. RoryD

    Anyone supply an idiots guide to DIY powerflushing

    puddle you're digging out BG engineers again! BG don't do that at all and BG do not refuse ANYONE a contract on the grounds they have sludge, quite the contrary. I as an engineer would point the issues out, because that's best advice, which I'd hope everyone would give. This contract would be...