Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. B

    Vaillant TURBOMax Plus 828E - Partial Load Setting d.00 problems

    Hi, I have a TURBOMax Plus 828E in a small Annex that only has 3 Rads. The boiler Cycles but is only ignited for about 30-40 seconds before reaching target Temp and then goes on pump overrun. Given that there are only 3 Rads and are 'designer' with a total combined KW spec of about 2.5kw, the...
  2. B

    Mixed UFH and Radiators: Setting Return Flow Temperature control ?

    I have a system with 14 UFH Circuits on the ground floor and 21 Radiators upstairs. We primarily use the UFH plus a few Bathroom rads and then a Rads in very cold weather. I’ve always run the system with the Boiler operating based on - Target Flow Temp setting, but am wondering if anybody has...
  3. B

    Ideal Vogue S32 Gen2 occasional ‘NO WATER FLOW FAULT’

    Hi, Following an Anglia Water complete loss of Water Supply in Milton Keynes, I had a call from a Tenant reporting the No Water Flow Fault On the Ideal S32 Gen2. When I arrived at the property I found the pressure in the System Loop was absolute zero. There were boiler manual papers out in the...
  4. B

    Pressure Drop with Hot Water flow - Ideal Vogue S32 Gen 2

    Hi there, I have a Vogue S32 Gen 2 in an empty rental property and noticed that the Boiler Pressure Gauge was high at about 3 bar. It may be that the old Tenants over pressured it with the filling loop, as I’ve certainly only filled it to 1.5 bar historically. I drained down the CH water...
  5. B

    Secondary Return Pump Noise / Air ?

    Hi, Recently I noticed that we were running out of HW more than expected, perhaps it’s people are taking more baths but I wanted to check out if the pair of Vaillant uniSTOR’s were both heating, thinking that maybe I had a problem with one of the Zone Valves were not heating one of the tanks...
  6. B

    HW Gas consumption for empty house ?

    Hi all, Bit of an odd question here. I've been on holiday and have the CH switched off, but did not stop the twice daily boost of HW on the timer. Given that here is no HW been consumed in the house when we are away I expected the gas consumption to be minimal as the loss from the 2 x uniSTOR...
  7. B

    Thermostatic Blending Valve Identification

    Hi All, Can anybody identify this Thermostatic Blending Valve from my Underfloor heating ? It seems to be stuck on full temp and not mixing the cold flow.
  8. B

    Hansgrohe Ecostat - Thermostatic Mixer Handle removal

    For the life of me I can't seem to find the way to remove the Thermostatic handle. The Hansgrohe Ecostat web pages seem to i cage a simple flat scre. https://spares.hansgrohe.com/etk/INT/pdf/datasheet.pdf?art=15375000&partlist=8796268539747&lang=en_GB However mine is not and neither is it a...
  9. B

    Wanted: Plumber to lay UPONOR MLCP in 1 room

    Hi, I am replacing the screed and pipe in one Conservatory room as the screed was shot and breaking up after ceramic tiles were lifted by my tiler. To be fair the screed must have been a bad mix or dried to rapidly in the conservatory heat. Currently the whole system (14 loops) use UNIPIPE...
  10. B

    Not all Radiators getting hot !!

    Hi, Some of my radiators are not getting hot at all or some are just hot at the top and from one side. System Description. - Downstairs mostly Wet Under Floor Heating. 14 Flow Circuits, with 8 Room Stats / Zones - WORKING OK 1 Towel Rad fed from upstairs - Upstairs - Radiator based, single...
  11. B

    Blocked 10mm Speedfit Pipe to Towel Rad

    Hi, I have a blocked 10mm pipe to a Towel Rad. I have both ends disconnected (distribution manifold and Rad) but cant get any flow through it. I have tried mains hose on to one end, but it seems to hold firm. Its never works since I've been in the house (18 months) and the property is aprox...