Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. L

    Geberit aco 103 plus press tool advice.

    Hi. I've recently purchased a press tool which is branded geberit but it's actually a novopress aco 103. I was wondering if anyone knew if there was an adaptor that would fit so I can get the machine in tight spaces. I know Rems do a 45° attachment but not sure if this would fit in my...
  2. L

    Telford tempest cylinder fault?

    Hi I have a Telford tempest unvented cylinder and I'm finding that when the hot water is on and I turn it off on the programmer the TPRV opens and let's the hot water out. Only stops running when it cools down again. What I find strange is that it only happens if I turn the programmer off. If...
  3. L

    Viessmann vitodens 100 FF fault?

    Hi. I've been out to look at this boiler today (I am a gas engineer) and found that this FF fault code keeps coming up even after restarting the boiler. On arrival I found pressure was on zero so I topped it back up and reset the boiler. On the display it says 141 then changes to...
  4. L

    showermax supercal cylinder

    Hi I've been out to look at this job where this cylinder has been installed for over 15yrs now. Hot water works fine on the gravity fed side but the mains going through the cylinder for the shower feed doesn't stay hot. It will last a few seconds then runs cold. Is there a fault inside the...
  5. L

    Glowworm 30cxi f12 fault code?

    Hi. I'm currently working on repairing this boiler. What are the most common faults with f12 error code? When turning the boiler on it reads 0.0bar and I can hear the fan constantly running but nothing else the goes to f12. After a while it will then come off f12 and fire up. This...
  6. L

    Ideal isar 30he

    Hi Servicing this boiler and I have found the inlet working pressure is 12-13mbar when hot tap is running. At the meter is 24mbar working. 26mbar standing. Would this be classed as At risk? Ideal has mentioned it would be as it would cause incomplete combustion. Anything below 14mbar...
  7. L

    Baxi combi 105he fault.

    Hi. I'm working on this boiler and the fault code is 30 and 50. Ive cleaned the venturi out. Air pressure switch clicks on. Fan runs fine. Anything else I can check? It works for a few days then fault appears again. I'm going back there now to check if the air pressure switch power if...
  8. L

    Boiler Pressure Problems.

    Hi. I'm having problems with finding the reason for that pressure to keep falling to 0. The customer rang me saying it took 4 hours for it to drop but I'd image he had it on all that time. When I went out I checked the pressure relief valve, drained the boiler and recharged the expansion...
  9. L

    Glow Worm 30CXI F12 Fault.

    Hi I need help with this fault code F12. Every time i go to the job its on F and then solid red light or F12 and red light. But when i turn it off and on and test it everything works until a few hours later i get a phone call saying its gone to F12 again. I have in my van the PCB board and...
Back