  1. G

    Worcester greenstar 42cdi heating issue

    H everyone havnt posted for a while hope everyone is good. Got a call to above boiler today customer saying fault with heating and e9 fault code showing. Hot water is fine. I couldnt get fault code to appear but looking in manual e9 states overheat issue. All thats happening is pump pulsates for...
  2. G

    replacing ideal classic with logic heat

    hi guys going to be taking out ideal classic and replacing with ideal logic heat 18. my only issue is the wiring with the pump as the classic only has the live, neutral, earth at boiler connections whereas the new logic's have the pump wiring at boiler also requiring a permanent live. was...
  3. G

    fitting new heating filter

    been to price up heating job today. customers doesnt want to see any pipes so using stand off kit. Problem i have is wanting to put a decent filter on system but with pipes going up behind boiler and its going to be in tight cupboard and no room above boiler. any suggestions on fitting filter...
  4. G

    worcester greenstar cdi flow unit

    went to above boiler and found the plastic flow unit had a pin hole. just wondered if you guys had any heads up regarding changing it. do i need to take out hydraulic block. Also ive got hardly any access underneath boiler either.
  5. G

    Worcester CSI rsf diverter change

    Changing the diverter in above boiler tomorrow. Just wanted some heads up as its first time and have heard it can be quite awkward. The part came today and it had with it a few washers and o rings which seems one bonus at least. How long would you reckon I could be looking at to change it bear...
  6. G

    Ideal Logic + no hot water

    Called out today to above boiler. Heating fine but no hot water. Hall sensor is flasing red when demand for hot water but thats it. the motorised head moves fine for central heating but nothing for hot water. Could the head still be faulty if it moves for heating? any help appreciated.
  7. G

    vaillant vcv aps

    been to above boiler no heating or hot water. pump runs, fan spins no spark. took hose of aps and sucked in tube fired up straight away. i am thinking blocked venturi but could aps still be faulty even though im forcing it to light?
  8. G

    worcester 28i junior

    tomorrows first job in morning. customer phoned to say hot water fine but heating is coming or for about 30 secs then cutting out and not coming back on till reset. just wondered if anyone has advice on these boilers. any advice very appreciated.
  9. G

    ideal isar flue

    anyone know if you can still get the flues for these heaps of crap. customer is wanting boiler moved from bedroom into old airing cupboard and will need a vertical flue installing. fingers crossed i cant but thought i would check with you guys?
  10. G

    converting open vent to sealed

    one of my jobs tomorrow to remove existing f & e and change to sealed system. MI's state they like the vessel fitted on negative side of pump (flow), but i was wanting to fit to return (no valves or restrictions) just wondered why they would state on flow rather than return as i thought less...
  11. G

    potterton apollo e133

    got call last thing today to go look at boiler. was thinking electrodes or no gas. when i turned up the boiler is doing some strange things. when call for hw the boiler ignites then out, back on for a short while before lock out with e133 code and hot water light flashing. quickly checked gas...
  12. G

    replacing duo tec with either potterton gold or main eco

    just wondering if both these boilers fit existing jig and also flue terminal is in same position?
  13. G

    converting to fully pumped system

    hi guys im converting a gravity hot water with pumped heating to a fully pumped system. My question is im taking out old 28mm circs and replacing with 22mm what is the rule on the t on the shared return?
  14. G

    baxi duo tec flue adapter seals

    anyone know the baxi product number for the 2 seals for the flue adapter, looked on net but cant find them. Baxi 5112369 flue adaptor he (no seals)
  15. G

    potterton profile 80el

    got called to boiler last thing today when call for heat fan just humming not spinning no spark. going back in morning as had not time to have better look, wondered if anyone had any pointers on these boilers?
  16. G

    plumb center wireless stat

    anyone know if the center wireless room stats relay box can fit straight onto backplate of the honeywell cm927. im sure i heard somewhere you can.
  17. G

    what boilers do you recommend

    got to price up combi boiler for good customer. i have been fitting ideal logic + or baxi platinums of late. is there any other boilers you guys like to fit with decent warranties?
  18. G

    baxi duo tec very high emissions

    hi guys. got call to above boiler today for routine service. as soon as started to analyse it the readings were off the scale was going up to 5000 pm before removing my analyser. i checked for flue integrity and was getting over 600 pm. gas inlet pressure at full rate was 19mbar. its a vertical...
  19. G

    baxi 105 he pump light flashing

    Hi guys, just had customer on phone saying they got no hot water or heating with pump light flashing. they say they have 1.5 pressure and can hear pump running. Am i right in thinking this is usually the primary flow valve pin not lifting?
  20. G

    ideal logic + 30kw

    just installed one today. great boilers to fit must say. just one thing i noticed with it when i came to analyse it was the ratio was 0.0015. i know its below the trigger value, but it just seems high for new install. fitted the heat only version other day and ratio was 0.0002. are the combi...