Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. JLS

    Mains Inlet through loft

    Was asked to look at a Mains inlet today that the property owner wants moving. It currently comes into the hall in black HDPE , through a concrete slab and about 6 inches up the wall in copper, then poly up the wall and through the unheated loft space. It's not pretty, but at least whoever...
  2. JLS

    Gas Pipe exiting from side of meter box

    Is it permissible for a gas pipe to exit from the side of the meter box?
  3. JLS

    Pipe sizing questions

    Hi all, still working on my portfolio but having a bit of confusion regarding allowances for fittings when working out pipe size requirements as I'm reading conflicting information. In college we were told to allow 0.5m for Tees and elbows and 0.3m for bends. My Viper gas handbook says the same...
  4. JLS

    Boiler Plus 2018 regulations

    I'm a bit confused by these new regulations, specifically the: Combi boiler installations must also include one of the following: Weather compensation, Load compensation, Flue Gas Heat Recovery, Smart controls. I thought all new boilers had to be condensing for sometime now, so doesn't that...
  5. JLS

    Expansion vessel sizing question (because it's driving me mad)

    Hi all, I wonder if someone can explain something to me when it comes to expansion vessel sizing. On the basis of about 4% expansion at 100degrees one would think that for a 200l closed system an 8l expansion vessel would be sufficient, with a bit of a safety factor say 10l. Worcester...
  6. JLS

    Has anyone had any experience of a company named Runrec?

    Hi all, I'm looking to get Gas safe registered. In a fit of over zealous enthusiasm I did the three week foundation course and then like so many before me am finding it impossible to find anyone to do the portfolio with. Whilst looking for such opportunities I came across a company called...
Back
Top